CVE-2023-49251 Auth bypass in SIMATIC CN 4100

High 8.8 Published Updated

An attacker can add credentials during intermediate installation to gain remote root access on SIMATIC CN 4100 devices.

Exploited in the wild
Not known
Login needed
Any signed-in user
Attackable
Over the internet
Victim action needed
Not needed
Fix
None listed

What is CVE-2023-49251?

CVE-2023-49251 is a high-severity authentication bypass vulnerability in Siemens SIMATIC CN 4100, published on 9 Jan 2024. Any signed-in user can exploit it over the network, with no action from the victim.

Official description

A vulnerability has been identified in SIMATIC CN 4100 (All versions < V2.7). The "intermediate installation" system state of the affected application allows an attacker to add their own login credentials to the device. This allows an attacker to remotely login as root and take control of the device even after the affected device is fully set up.

Weakness: CWE-639

Which versions are affected by CVE-2023-49251?

It affects 1 product.

Products include Siemens Simatic Cn 4100 Firmware.

How do I fix CVE-2023-49251?

No fix has been published for CVE-2023-49251 yet. Limit exposure of the affected software until one is available.

Upgrade, and rotate credentials and sessions that may have been exposed. More about Authentication bypass.

Is CVE-2023-49251 being exploited?

There is no known exploitation of CVE-2023-49251 in the wild and no public exploit code.

Sources

Also known as GHSA-c4wm-h8mm-vr45.

Is CVE-2023-49251 in your software?

Upload an SBOM and sbomify checks it against every vulnerability here, every day.

Check your SBOMs for free