{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2023-49260 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2023-49260 yet. Limit exposure of the affected software until one is available.","what":"CVE-2023-49260 is a medium-severity cross-site scripting vulnerability in Hongdian H8951-4G-ESP, published on 12 Jan 2024. An attacker can exploit it over the internet without logging in, and only if a user opens a file or follows a link."},"fix_prompt":"Check this codebase for CVE-2023-49260 and fix it if it is affected.\n\nWhat it is: CVE-2023-49260 is a medium-severity cross-site scripting vulnerability in Hongdian H8951-4G-ESP, published on 12 Jan 2024. An attacker can exploit it over the internet without logging in, and only if a user opens a file or follows a link.\nExploitation: There is no known exploitation of CVE-2023-49260 in the wild and no public exploit code.\n\nAffected product: Hongdian H8951-4G-ESP. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2023-49260/ (Markdown: https://insights.sbomify.com/CVE-2023-49260/index.md)","id":"CVE-2023-49260","markdown":"https://insights.sbomify.com/CVE-2023-49260/index.md","name":"CVE-2023-49260","record":{"aliases":["GHSA-v64q-49fj-whh5"],"analysis":{"component_type":"network_device","fix_type":"no_fix_stated","impacts":["code_execution","account_takeover"],"network_reachable":"yes","non_default_config":false,"product_category":"Hongdian H8951-4G-ESP","requires_auth":"none","summary":"Attackers can inject malicious scripts via the MOTD banner to execute code or hijack sessions on Hongdian H8951-4G-ESP devices.","user_interaction":"required","vuln_class":"xss"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"CERT-PL","cpe":[{"product":"h8951-4g-esp_firmware","vendor":"hongdian"}],"cvss":{"score":6.1,"severity":"medium","source":"cisa-adp","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N","version":"3.1"},"cwes":[{"id":"CWE-79","name":"Improper Neutralization of Input During Web Page Generation"}],"description":"An XSS attack can be performed by changing the MOTD banner and pointing the victim to the \"terminal_tool.cgi\" path. It can be used together with the vulnerability CVE-2023-49255.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Stored cross-site scripting vulnerability","id":"CVE-2023-49260","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"xss","year":"2023"},"n_packages":0,"n_references":2,"next":{"headline":"Sensitive authentication-related value accessible publicly","id":"CVE-2023-49261"},"packages":[],"prev":{"headline":"Bruteforcing authentication cookie for a given user","id":"CVE-2023-49259"},"products":["H8951-4G-ESP"],"published":"2024-01-12","related":[{"cvss_score":9.8,"headline":"Predefined root password","id":"CVE-2023-49253","kev_date_added":null,"published":"2024-01-12"},{"cvss_score":9.8,"headline":"Router console accessible without authentication","id":"CVE-2023-49255","kev_date_added":null,"published":"2024-01-12"},{"cvss_score":9.8,"headline":"Buffer overflow vulnerability in Cookie authentication field","id":"CVE-2023-49262","kev_date_added":null,"published":"2024-01-12"},{"cvss_score":8.8,"headline":"Command injection in the network test tools","id":"CVE-2023-49254","kev_date_added":null,"published":"2024-01-12"},{"cvss_score":8.8,"headline":"Command execution using the certificate upload utility","id":"CVE-2023-49257","kev_date_added":null,"published":"2024-01-12"},{"cvss_score":7.5,"headline":"Predictable encryption passphrase used in publicly accessible configuration file","id":"CVE-2023-49256","kev_date_added":null,"published":"2024-01-12"},{"cvss_score":7.5,"headline":"Bruteforcing authentication cookie for a given user","id":"CVE-2023-49259","kev_date_added":null,"published":"2024-01-12"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"partial"},"state":"PUBLISHED","updated":"2025-06-03","vendors":["Hongdian"]},"summary":"Attackers can inject malicious scripts via the MOTD banner to execute code or hijack sessions on Hongdian H8951-4G-ESP devices.","url":"https://insights.sbomify.com/CVE-2023-49260/"}