{"answers":{"affected":"It affects 2 products.","exploited":"There is no known exploitation of CVE-2023-5389 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2023-5389 yet. Limit exposure of the affected software until one is available.","what":"CVE-2023-5389 is a critical vulnerability in Honeywell ControlEdge UOC, published on 30 Jan 2024. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2023-5389 and fix it if it is affected.\n\nWhat it is: CVE-2023-5389 is a critical vulnerability in Honeywell ControlEdge UOC, published on 30 Jan 2024. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2023-5389 in the wild and no public exploit code.\n\nAffected product: Honeywell ControlEdge UOC. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2023-5389/ (Markdown: https://insights.sbomify.com/CVE-2023-5389/index.md)","id":"CVE-2023-5389","markdown":"https://insights.sbomify.com/CVE-2023-5389/index.md","name":"CVE-2023-5389","record":{"aliases":["GHSA-h7wp-7q3v-7m5w"],"analysis":{"component_type":"ics_ot","fix_type":"upgrade","impacts":["data_modify","code_execution"],"network_reachable":"yes","non_default_config":false,"product_category":"Honeywell ControlEdge UOC","requires_auth":"none","summary":"An attacker can modify files on Honeywell ControlEdge UOC, potentially leading to unexpected behavior or execution of malicious applications.","user_interaction":"not_required","vuln_class":"file_upload"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"Honeywell","cpe":[{"product":"controledge_unit_operations_controller_firmware","vendor":"honeywell"},{"product":"controledge_virtual_unit_operations_controller_firmware","vendor":"honeywell"}],"cvss":{"score":9.1,"severity":"critical","source":"cna","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H","version":"3.1"},"cwes":[{"id":"CWE-749","name":"Exposed Dangerous Method or Function"}],"description":"An attacker could potentially exploit this vulnerability, leading to the ability to modify files on Honeywell Experion ControlEdge VirtualUOC and ControlEdge UOC . This exploit could be used to write a file that may result in unexpected behavior based on configuration changes or updating of files that could result in subsequent execution of a malicious application if triggered. Honeywell recommends updating to the most recent version of the product. See Honeywell Security Notification for recommendations on upgrading and versioning.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"File upload in ControlEdge UOC","id":"CVE-2023-5389","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"file_upload","year":"2023"},"n_packages":0,"n_references":2,"next":{"headline":"Path traversal in ControlEdge UOC","id":"CVE-2023-5390"},"packages":[],"prev":{"headline":"Information disclosure in Firefox","id":"CVE-2023-5388"},"products":["ControlEdge UOC"],"published":"2024-01-30","related":[{"cvss_score":5.3,"headline":"Path traversal in ControlEdge UOC","id":"CVE-2023-5390","kev_date_added":null,"published":"2024-01-31"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"total"},"state":"PUBLISHED","updated":"2025-06-17","vendors":["Honeywell"]},"summary":"An attacker can modify files on Honeywell ControlEdge UOC, potentially leading to unexpected behavior or execution of malicious applications.","url":"https://insights.sbomify.com/CVE-2023-5389/"}