{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2023-5986 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2023-5986 yet. Limit exposure of the affected software until one is available.","what":"CVE-2023-5986 is a high-severity vulnerability in Schneider Electric EcoStruxure Power Monitoring Expert (PME), published on 15 Nov 2023. An attacker can exploit it over the internet without logging in, and only if a user opens a file or follows a link."},"fix_prompt":"Check this codebase for CVE-2023-5986 and fix it if it is affected.\n\nWhat it is: CVE-2023-5986 is a high-severity vulnerability in Schneider Electric EcoStruxure Power Monitoring Expert (PME), published on 15 Nov 2023. An attacker can exploit it over the internet without logging in, and only if a user opens a file or follows a link.\nExploitation: There is no known exploitation of CVE-2023-5986 in the wild and no public exploit code.\n\nAffected product: Schneider Electric EcoStruxure Power Monitoring Expert (PME). No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2023-5986/ (Markdown: https://insights.sbomify.com/CVE-2023-5986/index.md)","id":"CVE-2023-5986","markdown":"https://insights.sbomify.com/CVE-2023-5986/index.md","name":"CVE-2023-5986","record":{"aliases":["GHSA-grp5-2x24-q4vj"],"analysis":{"component_type":"web_application","fix_type":"patch","impacts":["security_bypass"],"network_reachable":"yes","non_default_config":false,"product_category":"EcoStruxure Power Monitoring","requires_auth":"none","summary":"Attackers can redirect users to malicious sites after login, potentially enabling phishing or cross-site scripting attacks in Schneider Electric power monitoring applications.","user_interaction":"required","vuln_class":"open_redirect"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"schneider","cpe":[{"product":"ecostruxure_power_monitoring_expert","vendor":"schneider-electric"}],"cvss":{"score":8.2,"severity":"high","source":"cna","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:H/I:L/A:N","version":"3.1"},"cwes":[{"id":"CWE-601","name":"URL Redirection to Untrusted Site"}],"description":"A CWE-601 URL Redirection to Untrusted Site vulnerability exists that could cause an openredirect vulnerability leading to a cross site scripting attack. By providing a URL-encoded input\nattackers can cause the software’s web application to redirect to the chosen domain after a\nsuccessful login is performed.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Open redirect in EcoStruxure Power Monitoring Expert (PME)","id":"CVE-2023-5986","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"open_redirect","year":"2023"},"n_packages":0,"n_references":1,"next":{"headline":"Cross-site scripting in EcoStruxure Power Monitoring Expert (PME)","id":"CVE-2023-5987"},"packages":[],"prev":{"headline":"Cross-site scripting in ION8650","id":"CVE-2023-5985"},"products":["EcoStruxure Power Monitoring Expert (PME)","EcoStruxure Power Operation (EPO) – Advanced Reporting and Dashboards Module","EcoStruxure Power SCADA Operation (PSO) - Advanced Reporting and Dashboards Module"],"published":"2023-11-15","related":[{"cvss_score":9.8,"headline":"Deserialization in EcoStruxure Power Monitoring Expert","id":"CVE-2023-5391","kev_date_added":null,"published":"2023-10-04"},{"cvss_score":8.8,"headline":"Other in EcoStruxure Power Monitoring Expert (Versions 2020 and prior)","id":"CVE-2022-22727","kev_date_added":null,"published":"2022-02-04"},{"cvss_score":8.8,"headline":"Code injection in n/a","id":"CVE-2021-22826","kev_date_added":null,"published":"2022-01-28"},{"cvss_score":8.8,"headline":"Code injection in n/a","id":"CVE-2021-22827","kev_date_added":null,"published":"2022-01-28"},{"cvss_score":8.5,"headline":"Deserialization in EcoStruxure™ Power Monitoring Expert (PME)","id":"CVE-2025-11739","kev_date_added":null,"published":"2026-03-10"},{"cvss_score":6.7,"headline":"Auth bypass in EcoStruxure Power Monitoring Expert","id":"CVE-2023-28003","kev_date_added":null,"published":"2023-04-18"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"partial"},"state":"PUBLISHED","updated":"2024-12-02","vendors":["Schneider Electric"]},"summary":"Attackers can redirect users to malicious sites after login, potentially enabling phishing or cross-site scripting attacks in Schneider Electric power monitoring applications.","url":"https://insights.sbomify.com/CVE-2023-5986/"}