{"answers":{"affected":"It affects 1 product.","exploited":"It is not confirmed as exploited in the wild, but public exploit code for CVE-2024-0541 exists.","fix":"No fix has been published for CVE-2024-0541 yet. Limit exposure of the affected software until one is available.","what":"CVE-2024-0541 is a high-severity memory corruption vulnerability in Tenda W9, published on 15 Jan 2024. Any signed-in user can exploit it over the network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2024-0541 and fix it if it is affected.\n\nWhat it is: CVE-2024-0541 is a high-severity memory corruption vulnerability in Tenda W9, published on 15 Jan 2024. Any signed-in user can exploit it over the network, with no action from the victim.\nExploitation: It is not confirmed as exploited in the wild, but public exploit code for CVE-2024-0541 exists.\n\nAffected product: Tenda W9. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2024-0541/ (Markdown: https://insights.sbomify.com/CVE-2024-0541/index.md)","id":"CVE-2024-0541","markdown":"https://insights.sbomify.com/CVE-2024-0541/index.md","name":"CVE-2024-0541","record":{"aliases":["GHSA-cmp3-jfp5-m6fq"],"analysis":{"component_type":"network_device","fix_type":"no_fix_stated","impacts":["code_execution"],"network_reachable":"yes","non_default_config":false,"product_category":"Tenda W9 router","requires_auth":"low_privilege","summary":"Remote attackers can trigger a stack-based buffer overflow in the Tenda W9 router's httpd service to execute arbitrary code.","user_interaction":"not_required","vuln_class":"memory_corruption"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"VulDB","cpe":[{"product":"w9_firmware","vendor":"tenda"}],"cvss":{"score":8.8,"severity":"high","source":"cna","vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","version":"3.1"},"cwes":[{"id":"CWE-787","name":"Out-of-bounds Write"},{"id":"CWE-121","name":"Stack-based Buffer Overflow"}],"description":"A vulnerability was found in Tenda W9 1.0.0.7(4456). It has been declared as critical. Affected by this vulnerability is the function formAddSysLogRule of the component httpd. The manipulation of the argument sysRulenEn leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-250711. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"weaponised"},"has_fix":null,"headline":"Tenda W9 httpd formAddSysLogRule stack-based overflow","id":"CVE-2024-0541","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"memory_corruption","year":"2024"},"n_packages":0,"n_references":3,"next":{"headline":"Tenda W9 httpd formWifiMacFilterGet stack-based overflow","id":"CVE-2024-0542"},"packages":[],"prev":{"headline":"Tenda W9 httpd formOfflineSet stack-based overflow","id":"CVE-2024-0540"},"products":["W9"],"published":"2024-01-15","related":[{"cvss_score":9.8,"headline":"Memory corruption in n/a","id":"CVE-2023-51097","kev_date_added":null,"published":"2023-12-26"},{"cvss_score":9.8,"headline":"Command injection in n/a","id":"CVE-2023-51098","kev_date_added":null,"published":"2023-12-26"},{"cvss_score":9.8,"headline":"Command injection in n/a","id":"CVE-2023-51099","kev_date_added":null,"published":"2023-12-26"},{"cvss_score":9.8,"headline":"Command injection in n/a","id":"CVE-2023-51100","kev_date_added":null,"published":"2023-12-26"},{"cvss_score":9.8,"headline":"Memory corruption in n/a","id":"CVE-2023-51101","kev_date_added":null,"published":"2023-12-26"},{"cvss_score":9.8,"headline":"Memory corruption in n/a","id":"CVE-2023-51102","kev_date_added":null,"published":"2023-12-26"},{"cvss_score":8.8,"headline":"Tenda W9 formQosManageDouble_user stack-based overflow","id":"CVE-2024-4240","kev_date_added":null,"published":"2024-04-26"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"poc","technical_impact":"total"},"state":"PUBLISHED","updated":"2025-05-12","vendors":["Tenda"]},"summary":"Remote attackers can trigger a stack-based buffer overflow in the Tenda W9 router's httpd service to execute arbitrary code.","url":"https://insights.sbomify.com/CVE-2024-0541/"}