{"answers":{"affected":"It affects 1 product.","exploited":"It is not confirmed as exploited in the wild, but public exploit code for CVE-2024-0927 exists.","fix":"No fix has been published for CVE-2024-0927 yet. Limit exposure of the affected software until one is available.","what":"CVE-2024-0927 is a medium-severity memory corruption vulnerability in Tenda AC10U, published on 26 Jan 2024. An attacker needs administrator access to exploit it, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2024-0927 and fix it if it is affected.\n\nWhat it is: CVE-2024-0927 is a medium-severity memory corruption vulnerability in Tenda AC10U, published on 26 Jan 2024. An attacker needs administrator access to exploit it, with no action from the victim.\nExploitation: It is not confirmed as exploited in the wild, but public exploit code for CVE-2024-0927 exists.\n\nAffected product: Tenda AC10U. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2024-0927/ (Markdown: https://insights.sbomify.com/CVE-2024-0927/index.md)","id":"CVE-2024-0927","markdown":"https://insights.sbomify.com/CVE-2024-0927/index.md","name":"CVE-2024-0927","record":{"aliases":["GHSA-h3cr-9vp8-wwcx"],"analysis":{"component_type":"network_device","fix_type":"no_fix_stated","impacts":["code_execution"],"network_reachable":"yes","non_default_config":false,"product_category":"Tenda AC10U router","requires_auth":"high_privilege","summary":"Remote attackers can trigger a stack-based buffer overflow in the Tenda AC10U router via crafted network requests, potentially leading to arbitrary code execution.","user_interaction":"not_required","vuln_class":"memory_corruption"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"VulDB","cpe":[{"product":"ac10u_firmware","vendor":"tendacn"}],"cvss":{"score":4.7,"severity":"medium","source":"cna","vector":"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:L","version":"3.1"},"cwes":[{"id":"CWE-121","name":"Stack-based Buffer Overflow"}],"description":"A vulnerability was found in Tenda AC10U 15.03.06.49_multi_TDE01. It has been classified as critical. Affected is the function fromAddressNat. The manipulation of the argument entrys/mitInterface/page leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-252132. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"weaponised"},"has_fix":null,"headline":"Tenda AC10U fromAddressNat stack-based overflow","id":"CVE-2024-0927","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"memory_corruption","year":"2024"},"n_packages":0,"n_references":3,"next":{"headline":"Tenda AC10U fromDhcpListClient stack-based overflow","id":"CVE-2024-0928"},"packages":[],"prev":{"headline":"Tenda AC10U formWifiWpsOOB stack-based overflow","id":"CVE-2024-0926"},"products":["AC10U"],"published":"2024-01-26","related":[{"cvss_score":9.8,"headline":"Memory corruption in n/a","id":"CVE-2023-44020","kev_date_added":null,"published":"2023-09-27"},{"cvss_score":9.8,"headline":"Memory corruption in n/a","id":"CVE-2023-44021","kev_date_added":null,"published":"2023-09-27"},{"cvss_score":9.8,"headline":"Memory corruption in n/a","id":"CVE-2023-44022","kev_date_added":null,"published":"2023-09-27"},{"cvss_score":9.8,"headline":"Memory corruption in n/a","id":"CVE-2023-44023","kev_date_added":null,"published":"2023-09-27"},{"cvss_score":9.8,"headline":"Command injection in n/a","id":"CVE-2021-45401","kev_date_added":null,"published":"2022-02-18"},{"cvss_score":9.8,"headline":"Memory corruption in n/a","id":"CVE-2020-22079","kev_date_added":null,"published":"2021-10-29"},{"cvss_score":8.8,"headline":"Memory corruption in n/a","id":"CVE-2023-44013","kev_date_added":null,"published":"2023-09-27"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"poc","technical_impact":"partial"},"state":"PUBLISHED","updated":"2025-05-29","vendors":["Tenda"]},"summary":"Remote attackers can trigger a stack-based buffer overflow in the Tenda AC10U router via crafted network requests, potentially leading to arbitrary code execution.","url":"https://insights.sbomify.com/CVE-2024-0927/"}