{"answers":{"affected":"","exploited":"There is no known exploitation of CVE-2024-10083 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2024-10083 yet. Limit exposure of the affected software until one is available.","what":"CVE-2024-10083 is a medium-severity denial of service vulnerability in Schneider Electric Uni-Telway driver, published on 13 Feb 2025. It can only be exploited from the same machine or local network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2024-10083 and fix it if it is affected.\n\nWhat it is: CVE-2024-10083 is a medium-severity denial of service vulnerability in Schneider Electric Uni-Telway driver, published on 13 Feb 2025. It can only be exploited from the same machine or local network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2024-10083 in the wild and no public exploit code.\n\nAffected product: Schneider Electric Uni-Telway driver. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2024-10083/ (Markdown: https://insights.sbomify.com/CVE-2024-10083/index.md)","id":"CVE-2024-10083","markdown":"https://insights.sbomify.com/CVE-2024-10083/index.md","name":"CVE-2024-10083","record":{"aliases":["GHSA-5gwh-6w25-xjxx"],"analysis":{"component_type":"ics_ot","fix_type":"patch","impacts":["denial_of_service"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"Schneider Electric ICS","requires_auth":"low_privilege","summary":"An authenticated local user can cause a denial of service on engineering workstations by invoking a specific driver interface with crafted input.","user_interaction":"not_required","vuln_class":"denial_of_service"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"schneider","cpe":[],"cvss":{"score":6.8,"severity":"medium","source":"cna","vector":"CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N","version":"4.0"},"cwes":[{"id":"CWE-20","name":"Improper Input Validation"}],"description":"CWE-20: Improper Input Validation vulnerability exists that could cause denial of service of engineering\nworkstation when specific driver interface is invoked locally by an authenticated user with crafted input.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Denial of service in Uni-Telway driver","id":"CVE-2024-10083","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"denial_of_service","year":"2024"},"n_packages":0,"n_references":1,"next":{"headline":"Contact Form 7 – Dynamic Text Extension \u003c= 4.5 - Information Disclosure via Shortcode","id":"CVE-2024-10084"},"packages":[],"prev":{"headline":"codechecker authentication method confusion vulnerability allows logging in as the built-in root user from an external service","id":"CVE-2024-10082"},"products":["Uni-Telway driver","Uni-Telway driver used in EcoStruxure Control Expert","Uni-Telway driver used in EcoStruxure Process Expert","Uni-Telway driver used in EcoStruxure Process Expert for AVEVA System Platform","Uni-Telway driver used in OPC Factory Server"],"published":"2025-02-13","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"partial"},"state":"PUBLISHED","updated":"2025-02-13","vendors":["Schneider Electric"]},"summary":"An authenticated local user can cause a denial of service on engineering workstations by invoking a specific driver interface with crafted input.","url":"https://insights.sbomify.com/CVE-2024-10083/"}