{"answers":{"affected":"","exploited":"There is no known exploitation of CVE-2024-10085 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2024-10085 yet. Limit exposure of the affected software until one is available.","what":"CVE-2024-10085 is a high-severity denial of service vulnerability in Schneider Electric EcoStruxure™ Modicon Communication Server, published on 1 Sep 2026. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2024-10085 and fix it if it is affected.\n\nWhat it is: CVE-2024-10085 is a high-severity denial of service vulnerability in Schneider Electric EcoStruxure™ Modicon Communication Server, published on 1 Sep 2026. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2024-10085 in the wild and no public exploit code.\n\nAffected product: Schneider Electric EcoStruxure™ Modicon Communication Server. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2024-10085/ (Markdown: https://insights.sbomify.com/CVE-2024-10085/index.md)","id":"CVE-2024-10085","markdown":"https://insights.sbomify.com/CVE-2024-10085/index.md","name":"CVE-2024-10085","record":{"aliases":["GHSA-qjm6-736g-f96f"],"analysis":{"component_type":"ics_ot","fix_type":"patch","impacts":["denial_of_service"],"network_reachable":"yes","non_default_config":false,"product_category":"OPC UA communication server","requires_auth":"none","summary":"Attackers can cause denial of service on Schneider Electric OPC UA platforms by sending excessive requests, impacting industrial communication availability.","user_interaction":"not_required","vuln_class":"denial_of_service"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"schneider","cpe":[],"cvss":{"score":8.2,"severity":"high","source":"cna","vector":"CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N","version":"4.0"},"cwes":[{"id":"CWE-770","name":"Allocation of Resources Without Limits or Throttling"}],"description":"CWE-770: Allocation of Resources Without Limits or Throttling vulnerability exists that could cause denial of service of the OPC UA communication platform when a large number of OPC UA requests are sent to the platform.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Denial of service in EcoStruxure™ Modicon Communication Server","id":"CVE-2024-10085","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"denial_of_service","year":"2024"},"n_packages":0,"n_references":1,"next":{"headline":"Consul Vulnerable To Reflected XSS On Content-Type Error Manipulation","id":"CVE-2024-10086"},"packages":[],"prev":{"headline":"Contact Form 7 – Dynamic Text Extension \u003c= 4.5 - Information Disclosure via Shortcode","id":"CVE-2024-10084"},"products":["EcoStruxure™ Modicon Communication Server","EcoStruxure™ OPC UA Server Expert"],"published":"2026-09-01","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"partial"},"state":"PUBLISHED","updated":"2026-09-01","vendors":["Schneider Electric"]},"summary":"Attackers can cause denial of service on Schneider Electric OPC UA platforms by sending excessive requests, impacting industrial communication availability.","url":"https://insights.sbomify.com/CVE-2024-10085/"}