{"answers":{"affected":"It affects 1 product.","exploited":"It is not confirmed as exploited in the wild, but public exploit code for CVE-2024-10130 exists.","fix":"No fix has been published for CVE-2024-10130 yet. Limit exposure of the affected software until one is available.","what":"CVE-2024-10130 is a high-severity memory corruption vulnerability in Tenda Ac8 Firmware, published on 18 Oct 2024. Any signed-in user can exploit it over the network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2024-10130 and fix it if it is affected.\n\nWhat it is: CVE-2024-10130 is a high-severity memory corruption vulnerability in Tenda Ac8 Firmware, published on 18 Oct 2024. Any signed-in user can exploit it over the network, with no action from the victim.\nExploitation: It is not confirmed as exploited in the wild, but public exploit code for CVE-2024-10130 exists.\n\nAffected product: Tenda Ac8 Firmware. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2024-10130/ (Markdown: https://insights.sbomify.com/CVE-2024-10130/index.md)","id":"CVE-2024-10130","markdown":"https://insights.sbomify.com/CVE-2024-10130/index.md","name":"CVE-2024-10130","record":{"aliases":["GHSA-6prf-mxrq-j35h"],"analysis":{"component_type":"network_device","fix_type":"no_fix_stated","impacts":["code_execution"],"network_reachable":"yes","non_default_config":false,"product_category":"Tenda AC8 router","requires_auth":"low_privilege","summary":"Remote attackers can trigger a stack-based buffer overflow in the Tenda AC8 router's reboot timer configuration, potentially leading to arbitrary code execution.","user_interaction":"not_required","vuln_class":"memory_corruption"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"VulDB","cpe":[{"product":"ac8_firmware","vendor":"tenda"}],"cvss":{"score":8.7,"severity":"high","source":"cna","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","version":"4.0"},"cwes":[{"id":"CWE-121","name":"Stack-based Buffer Overflow"}],"description":"A vulnerability classified as critical was found in Tenda AC8 16.03.34.06. This vulnerability affects the function formSetRebootTimer of the file /goform/SetSysAutoRebbotCfg. The manipulation of the argument rebootTime leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"weaponised"},"has_fix":null,"headline":"Tenda AC8 SetSysAutoRebbotCfg formSetRebootTimer stack-based overflow","id":"CVE-2024-10130","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":"tenda:ac8_firmware","products":["tenda:ac8_firmware"],"type":"memory_corruption","year":"2024"},"n_packages":0,"n_references":5,"next":{"headline":"Remote Code Execution in infiniflow/ragflow","id":"CVE-2024-10131"},"packages":[],"prev":{"headline":"HFO4 shudong-share Share create_share.php sql injection","id":"CVE-2024-10129"},"products":["AC8"],"published":"2024-10-18","related":[{"cvss_score":9.8,"headline":"Memory corruption in n/a","id":"CVE-2025-29100","kev_date_added":null,"published":"2025-03-24"},{"cvss_score":9.8,"headline":"Memory corruption in n/a","id":"CVE-2025-25663","kev_date_added":null,"published":"2025-02-20"},{"cvss_score":9.8,"headline":"Memory corruption in n/a","id":"CVE-2025-25664","kev_date_added":null,"published":"2025-02-20"},{"cvss_score":9.8,"headline":"Memory corruption in n/a","id":"CVE-2025-25667","kev_date_added":null,"published":"2025-02-20"},{"cvss_score":9.8,"headline":"Memory corruption in n/a","id":"CVE-2025-25668","kev_date_added":null,"published":"2025-02-20"},{"cvss_score":9.8,"headline":"Memory corruption in n/a","id":"CVE-2024-46652","kev_date_added":null,"published":"2024-09-20"},{"cvss_score":9.8,"headline":"Tenda AC8 formSetDeviceName stack-based overflow","id":"CVE-2023-4744","kev_date_added":null,"published":"2023-09-03"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"poc","technical_impact":"total"},"state":"PUBLISHED","updated":"2024-10-21","vendors":["Tenda"]},"summary":"Remote attackers can trigger a stack-based buffer overflow in the Tenda AC8 router's reboot timer configuration, potentially leading to arbitrary code execution.","url":"https://insights.sbomify.com/CVE-2024-10130/"}