{"answers":{"affected":"It affects 1 product.","exploited":"It is not confirmed as exploited in the wild, but public exploit code for CVE-2024-1014 exists.","fix":"No fix has been published for CVE-2024-1014 yet. Limit exposure of the affected software until one is available.","what":"CVE-2024-1014 is a medium-severity denial of service vulnerability in SE-elektronic GmbH E-DDC3.3, published on 29 Jan 2024. It can only be exploited from the same machine or local network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2024-1014 and fix it if it is affected.\n\nWhat it is: CVE-2024-1014 is a medium-severity denial of service vulnerability in SE-elektronic GmbH E-DDC3.3, published on 29 Jan 2024. It can only be exploited from the same machine or local network, with no action from the victim.\nExploitation: It is not confirmed as exploited in the wild, but public exploit code for CVE-2024-1014 exists.\n\nAffected product: SE-elektronic GmbH E-DDC3.3. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2024-1014/ (Markdown: https://insights.sbomify.com/CVE-2024-1014/index.md)","id":"CVE-2024-1014","markdown":"https://insights.sbomify.com/CVE-2024-1014/index.md","name":"CVE-2024-1014","record":{"aliases":["GHSA-fp4h-ppqj-prv5"],"analysis":{"component_type":"ics_ot","fix_type":"patch","impacts":["denial_of_service"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"SE-elektronic E-DDC3.3","requires_auth":"none","summary":"An attacker can disrupt the availability of the administration panel by sending multiple ICMP packets to the SE-elektronic E-DDC3.3 device.","user_interaction":"not_required","vuln_class":"denial_of_service"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"INCIBE","cpe":[{"product":"e-ddc3.3_firmware","vendor":"se-elektronic"}],"cvss":{"score":6.2,"severity":"medium","source":"cna","vector":"CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","version":"3.1"},"cwes":[{"id":"CWE-400","name":"Uncontrolled Resource Consumption"}],"description":"Uncontrolled resource consumption vulnerability in SE-elektronic GmbH E-DDC3.3 affecting versions 03.07.03 and higher. An attacker could interrupt the availability of the administration panel by sending multiple ICMP packets.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"weaponised"},"has_fix":null,"headline":"Uncontrolled resource consumption vulnerability in SE-elektronic GmbH E-DDC3.3","id":"CVE-2024-1014","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"denial_of_service","year":"2024"},"n_packages":0,"n_references":4,"next":{"headline":"Remote command execution vulnerability in SE-elektronic GmbH E-DDC3.3","id":"CVE-2024-1015"},"packages":[],"prev":{"headline":"Unixodbc: out of bounds stack write due to pointer-to-integer types conversion","id":"CVE-2024-1013"},"products":["E-DDC3.3"],"published":"2024-01-29","related":[{"cvss_score":9.8,"headline":"Remote command execution vulnerability in SE-elektronic GmbH E-DDC3.3","id":"CVE-2024-1015","kev_date_added":null,"published":"2024-01-29"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"poc","technical_impact":"partial"},"state":"PUBLISHED","updated":"2026-07-20","vendors":["SE-elektronic GmbH"]},"summary":"An attacker can disrupt the availability of the administration panel by sending multiple ICMP packets to the SE-elektronic E-DDC3.3 device.","url":"https://insights.sbomify.com/CVE-2024-1014/"}