{"answers":{"affected":"It affects 1 product.","exploited":"It is not confirmed as exploited in the wild, but public exploit code for CVE-2024-10267 exists.","fix":"No fix has been published for CVE-2024-10267 yet. Limit exposure of the affected software until one is available.","what":"CVE-2024-10267 is a high-severity vulnerability in transformeroptimus/superagi, published on 20 Mar 2025. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2024-10267 and fix it if it is affected.\n\nWhat it is: CVE-2024-10267 is a high-severity vulnerability in transformeroptimus/superagi, published on 20 Mar 2025. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: It is not confirmed as exploited in the wild, but public exploit code for CVE-2024-10267 exists.\n\nAffected product: transformeroptimus/superagi. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2024-10267/ (Markdown: https://insights.sbomify.com/CVE-2024-10267/index.md)","id":"CVE-2024-10267","markdown":"https://insights.sbomify.com/CVE-2024-10267/index.md","name":"CVE-2024-10267","record":{"aliases":["GHSA-8qff-6gwc-wph3"],"analysis":{"component_type":"web_application","fix_type":"no_fix_stated","impacts":["data_read"],"network_reachable":"yes","non_default_config":false,"product_category":"SuperAGI application","requires_auth":"none","summary":"Attackers can leak sensitive user data like emails and passwords by registering with an existing email address in SuperAGI.","user_interaction":"not_required","vuln_class":"information_disclosure"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"@huntr_ai","cpe":[{"product":"superagi","vendor":"superagi"}],"cvss":{"score":7.5,"severity":"high","source":"cna","vector":"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N","version":"3.0"},"cwes":[{"id":"CWE-359","name":"Exposure of Private Personal Information to an Unauthorized Actor"}],"description":"An information disclosure vulnerability exists in the latest version of transformeroptimus/superagi. An attacker can leak sensitive user information, including names, emails, and passwords, by attempting to register a new account with an email that is already in use. The server returns all information associated with the existing account. The vulnerable endpoint is located in the user registration functionality.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"weaponised"},"has_fix":false,"headline":"Information Disclosure in transformeroptimus/superagi","id":"CVE-2024-10267","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"information_disclosure","year":"2024"},"n_packages":0,"n_references":1,"next":{"headline":"Cross-site scripting in MP3 Audio Player – Music Player, Podcast Player \u0026 Radio by Sonaar","id":"CVE-2024-10268"},"packages":[],"prev":{"headline":"Cross-site scripting in Premium Addons for Elementor – Powerful Elementor Templates \u0026 Widgets","id":"CVE-2024-10266"},"products":["transformeroptimus/superagi"],"published":"2025-03-20","related":[{"cvss_score":8.8,"headline":"IDOR Vulnerability in transformeroptimus/superagi","id":"CVE-2024-12048","kev_date_added":null,"published":"2025-03-20"},{"cvss_score":8.8,"headline":"Path Traversal in transformeroptimus/superagi","id":"CVE-2024-9415","kev_date_added":null,"published":"2025-03-20"},{"cvss_score":8.8,"headline":"Remote Code Execution in transformeroptimus/superagi","id":"CVE-2024-9439","kev_date_added":null,"published":"2025-03-20"},{"cvss_score":7.5,"headline":"Unauthenticated Denial of Service in transformeroptimus/superagi","id":"CVE-2024-9437","kev_date_added":null,"published":"2025-03-20"},{"cvss_score":7.5,"headline":"Hardcoded credentials in n/a","id":"CVE-2023-48055","kev_date_added":null,"published":"2023-11-16"},{"cvss_score":6.5,"headline":"Code injection in n/a","id":"CVE-2025-51472","kev_date_added":null,"published":"2025-07-22"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"yes","exploitation":"poc","technical_impact":"partial"},"state":"PUBLISHED","updated":"2025-03-20","vendors":["transformeroptimus"]},"summary":"Attackers can leak sensitive user data like emails and passwords by registering with an existing email address in SuperAGI.","url":"https://insights.sbomify.com/CVE-2024-10267/"}