{"answers":{"affected":"It affects 1 product.","exploited":"It is not confirmed as exploited in the wild, but public exploit code for CVE-2024-10282 exists.","fix":"No fix has been published for CVE-2024-10282 yet. Limit exposure of the affected software until one is available.","what":"CVE-2024-10282 is a high-severity memory corruption vulnerability in Tenda RX9, published on 23 Oct 2024. Any signed-in user can exploit it over the network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2024-10282 and fix it if it is affected.\n\nWhat it is: CVE-2024-10282 is a high-severity memory corruption vulnerability in Tenda RX9, published on 23 Oct 2024. Any signed-in user can exploit it over the network, with no action from the victim.\nExploitation: It is not confirmed as exploited in the wild, but public exploit code for CVE-2024-10282 exists.\n\nAffected product: Tenda RX9. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2024-10282/ (Markdown: https://insights.sbomify.com/CVE-2024-10282/index.md)","id":"CVE-2024-10282","markdown":"https://insights.sbomify.com/CVE-2024-10282/index.md","name":"CVE-2024-10282","record":{"aliases":["GHSA-m3rv-2x75-rwgw"],"analysis":{"component_type":"network_device","fix_type":"no_fix_stated","impacts":["code_execution"],"network_reachable":"yes","non_default_config":false,"product_category":"Tenda WiFi router","requires_auth":"low_privilege","summary":"A remote attacker can trigger a stack-based buffer overflow in Tenda RX9 routers via the SetVirtualServerCfg endpoint, potentially leading to arbitrary code execution.","user_interaction":"not_required","vuln_class":"memory_corruption"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"VulDB","cpe":[{"product":"rx9_pro_firmware","vendor":"tenda"}],"cvss":{"score":8.7,"severity":"high","source":"cna","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","version":"4.0"},"cwes":[{"id":"CWE-787","name":"Out-of-bounds Write"},{"id":"CWE-121","name":"Stack-based Buffer Overflow"}],"description":"A vulnerability classified as critical was found in Tenda RX9 and RX9 Pro 22.03.02.10/22.03.02.20. Affected by this vulnerability is the function sub_42EA38 of the file /goform/SetVirtualServerCfg. The manipulation of the argument list leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"weaponised"},"has_fix":null,"headline":"Tenda RX9/RX9 Pro SetVirtualServerCfg sub_42EA38 stack-based overflow","id":"CVE-2024-10282","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"memory_corruption","year":"2024"},"n_packages":0,"n_references":5,"next":{"headline":"Tenda RX9/RX9 Pro SetNetControlList sub_4337EC stack-based overflow","id":"CVE-2024-10283"},"packages":[],"prev":{"headline":"Tenda RX9/RX9 Pro SetStaticRouteCfg sub_42EEE0 stack-based overflow","id":"CVE-2024-10281"},"products":["RX9","RX9 Pro"],"published":"2024-10-23","related":[{"cvss_score":9.8,"headline":"Memory corruption in n/a","id":"CVE-2022-38829","kev_date_added":null,"published":"2022-09-16"},{"cvss_score":9.8,"headline":"Memory corruption in n/a","id":"CVE-2022-38830","kev_date_added":null,"published":"2022-09-16"},{"cvss_score":9.8,"headline":"Memory corruption in n/a","id":"CVE-2022-38831","kev_date_added":null,"published":"2022-09-16"},{"cvss_score":8.7,"headline":"Tenda RX9 Pro POST Request setMacFilterCfg sub_424CE0 stack-based overflow","id":"CVE-2024-10351","kev_date_added":null,"published":"2024-10-24"},{"cvss_score":8.7,"headline":"Tenda RX9/RX9 Pro SetStaticRouteCfg sub_42EEE0 stack-based overflow","id":"CVE-2024-10281","kev_date_added":null,"published":"2024-10-23"},{"cvss_score":8.7,"headline":"Tenda RX9/RX9 Pro SetNetControlList sub_4337EC stack-based overflow","id":"CVE-2024-10283","kev_date_added":null,"published":"2024-10-23"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"poc","technical_impact":"partial"},"state":"PUBLISHED","updated":"2024-10-23","vendors":["Tenda"]},"summary":"A remote attacker can trigger a stack-based buffer overflow in Tenda RX9 routers via the SetVirtualServerCfg endpoint, potentially leading to arbitrary code execution.","url":"https://insights.sbomify.com/CVE-2024-10282/"}