{"answers":{"affected":"","exploited":"There is no known exploitation of CVE-2024-10334 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2024-10334 yet. Limit exposure of the affected software until one is available.","what":"CVE-2024-10334 is a high-severity vulnerability in ABB System 800xA, published on 10 Feb 2025. It can only be exploited from the same machine or local network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2024-10334 and fix it if it is affected.\n\nWhat it is: CVE-2024-10334 is a high-severity vulnerability in ABB System 800xA, published on 10 Feb 2025. It can only be exploited from the same machine or local network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2024-10334 in the wild and no public exploit code.\n\nAffected product: ABB System 800xA. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2024-10334/ (Markdown: https://insights.sbomify.com/CVE-2024-10334/index.md)","id":"CVE-2024-10334","markdown":"https://insights.sbomify.com/CVE-2024-10334/index.md","name":"CVE-2024-10334","record":{"aliases":["GHSA-7348-rmw4-rhvw"],"analysis":{"component_type":"ics_ot","fix_type":"patch","impacts":["data_read","data_modify"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"Industrial control system","requires_auth":"low_privilege","summary":"Attackers can access clear-text camera passwords to stop or manipulate video feeds in ABB System 800xA environments.","user_interaction":"not_required","vuln_class":"hardcoded_credentials"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"ABB","cpe":[],"cvss":{"score":7,"severity":"high","source":"cna","vector":"CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:L/VA:H/SC:N/SI:N/SA:N/S:N/AU:N/R:U/V:D/RE:M","version":"4.0"},"cwes":[{"id":"CWE-256","name":"Plaintext Storage of a Password"}],"description":"A vulnerability exists in the VideONet product included in the listed System 800xA versions, where VideONet is used. \n\nAn attacker who successfully exploited the vulnerability could, in the worst case scenario, stop or manipulate the video feed.\nThis issue affects System 800xA: 5.1.X; System 800xA: 6.0.3.X; System 800xA: 6.1.1.X; System 800xA: 6.2.X.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Camera passwords stored in clear text","id":"CVE-2024-10334","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"hardcoded_credentials","year":"2024"},"n_packages":0,"n_references":1,"next":{"headline":"SourceCodester Garbage Collection Management System login.php sql injection","id":"CVE-2024-10335"},"packages":[],"prev":{"headline":"Cross-site scripting in Janto","id":"CVE-2024-10332"},"products":["System 800xA"],"published":"2025-02-10","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"total"},"state":"PUBLISHED","updated":"2025-02-12","vendors":["ABB"]},"summary":"Attackers can access clear-text camera passwords to stop or manipulate video feeds in ABB System 800xA environments.","url":"https://insights.sbomify.com/CVE-2024-10334/"}