{"answers":{"affected":"","exploited":"There is no known exploitation of CVE-2024-10476 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2024-10476 yet. Limit exposure of the affected software until one is available.","what":"CVE-2024-10476 is a high-severity vulnerability in Becton Dickinson \u0026 Co BD BACTEC™ Blood Culture System, published on 17 Dec 2024. It can only be exploited from the same machine or local network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2024-10476 and fix it if it is affected.\n\nWhat it is: CVE-2024-10476 is a high-severity vulnerability in Becton Dickinson \u0026 Co BD BACTEC™ Blood Culture System, published on 17 Dec 2024. It can only be exploited from the same machine or local network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2024-10476 in the wild and no public exploit code.\n\nAffected product: Becton Dickinson \u0026 Co BD BACTEC™ Blood Culture System. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2024-10476/ (Markdown: https://insights.sbomify.com/CVE-2024-10476/index.md)","id":"CVE-2024-10476","markdown":"https://insights.sbomify.com/CVE-2024-10476/index.md","name":"CVE-2024-10476","record":{"aliases":["GHSA-2qgh-37rm-mv6x"],"analysis":{"component_type":"iot_embedded","fix_type":"configuration_change","impacts":["data_read","data_modify","denial_of_service"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"BD medical diagnostic systems","requires_auth":"low_privilege","summary":"Attackers can use default credentials to access, modify, or delete sensitive medical data and disrupt system availability in BD diagnostic products.","user_interaction":"not_required","vuln_class":"hardcoded_credentials"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"BD","cpe":[],"cvss":{"score":8,"severity":"high","source":"cna","vector":"CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","version":"3.1"},"cwes":[{"id":"CWE-1392","name":"Use of Default Credentials"}],"description":"Default credentials are used in the above listed BD Diagnostic Solutions products. If exploited, threat actors may be able to access, modify or delete data, including sensitive information such as protected health information (PHI) and personally identifiable information (PII). Exploitation of this vulnerability may allow an attacker to shut down or otherwise impact the availability of the system. Note: BD Synapsys™ Informatics\nSolution is only in scope of\nthis vulnerability when\ninstalled on a NUC server. BD Synapsys™\nInformatics Solution installed\non a customer-provided virtual machine or on the BD Kiestra™ SCU hardware is\nnot in scope.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Hardcoded credentials in BD BACTEC™ Blood Culture System","id":"CVE-2024-10476","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"hardcoded_credentials","year":"2024"},"n_packages":0,"n_references":1,"next":{"headline":"LinZhaoguan pb-cms Permission Management Page admin#permissions cross site scripting","id":"CVE-2024-10477"},"packages":[],"prev":{"headline":"Lead Form Builder \u003c 1.9.8 - Admin+ Stored XSS","id":"CVE-2024-10475"},"products":["BD BACTEC™ Blood Culture System","BD COR™ System","BD EpiCenter™ Microbiology Data Management System","BD MAX™ System","BD Phoenix™ M50 Automated Microbiology System","BD Synapsys™ Informatics Solution"],"published":"2024-12-17","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"total"},"state":"PUBLISHED","updated":"2024-12-17","vendors":["Becton Dickinson \u0026 Co"]},"summary":"Attackers can use default credentials to access, modify, or delete sensitive medical data and disrupt system availability in BD diagnostic products.","url":"https://insights.sbomify.com/CVE-2024-10476/"}