{"answers":{"affected":"","exploited":"There is no known exploitation of CVE-2024-10498 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2024-10498 yet. Limit exposure of the affected software until one is available.","what":"CVE-2024-10498 is a medium-severity memory corruption vulnerability in Schneider Electric PowerLogic HDPM6000, published on 17 Jan 2025. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2024-10498 and fix it if it is affected.\n\nWhat it is: CVE-2024-10498 is a medium-severity memory corruption vulnerability in Schneider Electric PowerLogic HDPM6000, published on 17 Jan 2025. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2024-10498 in the wild and no public exploit code.\n\nAffected product: Schneider Electric PowerLogic HDPM6000. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2024-10498/ (Markdown: https://insights.sbomify.com/CVE-2024-10498/index.md)","id":"CVE-2024-10498","markdown":"https://insights.sbomify.com/CVE-2024-10498/index.md","name":"CVE-2024-10498","record":{"aliases":["GHSA-4cj2-2366-wgf3"],"analysis":{"component_type":"ics_ot","fix_type":"patch","impacts":["data_modify","denial_of_service"],"network_reachable":"yes","non_default_config":false,"product_category":"PowerLogic HDPM6000","requires_auth":"none","summary":"An attacker can send malicious Modbus packets to corrupt memory, modifying configuration values and causing loss of web interface functionality.","user_interaction":"not_required","vuln_class":"memory_corruption"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"schneider","cpe":[],"cvss":{"score":6.9,"severity":"medium","source":"cna","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:L/VA:L/SC:N/SI:N/SA:N","version":"4.0"},"cwes":[{"id":"CWE-119","name":"Improper Restriction of Operations within the Bounds of a Memory Buffer"}],"description":"CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists that\ncould allow an unauthorized attacker to modify configuration values outside of the normal range when the\nattacker sends specific Modbus write packets to the device which could result in invalid data or loss of web\ninterface functionality.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Memory corruption in PowerLogic HDPM6000","id":"CVE-2024-10498","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"memory_corruption","year":"2024"},"n_packages":0,"n_references":1,"next":{"headline":"AI-Engine \u003c 2.6.5 - Admin+ SQLi","id":"CVE-2024-10499"},"packages":[],"prev":{"headline":"Auth bypass in PowerLogic HDPM6000","id":"CVE-2024-10497"},"products":["PowerLogic HDPM6000"],"published":"2025-01-17","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"yes","exploitation":"none","technical_impact":"partial"},"state":"PUBLISHED","updated":"2025-02-12","vendors":["Schneider Electric"]},"summary":"An attacker can send malicious Modbus packets to corrupt memory, modifying configuration values and causing loss of web interface functionality.","url":"https://insights.sbomify.com/CVE-2024-10498/"}