{"answers":{"affected":"","exploited":"There is no known exploitation of CVE-2024-10511 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2024-10511 yet. Limit exposure of the affected software until one is available.","what":"CVE-2024-10511 is a medium-severity denial of service vulnerability in Schneider Electric PowerChute Serial Shutdown, published on 11 Dec 2024. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2024-10511 and fix it if it is affected.\n\nWhat it is: CVE-2024-10511 is a medium-severity denial of service vulnerability in Schneider Electric PowerChute Serial Shutdown, published on 11 Dec 2024. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2024-10511 in the wild and no public exploit code.\n\nAffected product: Schneider Electric PowerChute Serial Shutdown. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2024-10511/ (Markdown: https://insights.sbomify.com/CVE-2024-10511/index.md)","id":"CVE-2024-10511","markdown":"https://insights.sbomify.com/CVE-2024-10511/index.md","name":"CVE-2024-10511","record":{"aliases":["GHSA-x424-8ch7-2p52"],"analysis":{"component_type":"server_software","fix_type":"patch","impacts":["denial_of_service"],"network_reachable":"yes","non_default_config":false,"product_category":"PowerChute Serial Shutdown","requires_auth":"none","summary":"An attacker on the local network can cause denial of access to the web interface by repeatedly requesting the /accessdenied URL.","user_interaction":"not_required","vuln_class":"denial_of_service"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"schneider","cpe":[],"cvss":{"score":6.3,"severity":"medium","source":"cna","vector":"CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N","version":"4.0"},"cwes":[{"id":"CWE-287","name":"Improper Authentication"}],"description":"CWE-287: Improper Authentication vulnerability exists that could cause Denial of access to the web interface\nwhen someone on the local network repeatedly requests the /accessdenied URL.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":"2024-12-24","github_poc":1,"max_poc_stars":0,"metasploit":0,"nuclei":0,"refs":[{"date":"2024-12-24T20:50:20Z","kind":"github_poc","ref":"https://github.com/revengsmK/CVE-2024-10511","stars":0,"title":"Schneider Electric PowerChute Serial Shutdown vulnerability."}],"tier":"poc_unverified"},"has_fix":null,"headline":"Denial of service in PowerChute Serial Shutdown","id":"CVE-2024-10511","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"denial_of_service","year":"2024"},"n_packages":0,"n_references":1,"next":{"headline":"Path Traversal in mintplex-labs/anything-llm","id":"CVE-2024-10513"},"packages":[],"prev":{"headline":"adBuddy+ (AdBlocker Detection) by NetfunkDesign \u003c= 1.1.3 - Admin+ Stored XSS","id":"CVE-2024-10510"},"products":["PowerChute Serial Shutdown"],"published":"2024-12-11","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"},{"class":"open","licence":"CC0","name":"PoC-in-GitHub"}],"ssvc":{"automatable":"yes","exploitation":"none","technical_impact":"partial"},"state":"PUBLISHED","updated":"2024-12-11","vendors":["Schneider Electric"]},"summary":"An attacker on the local network can cause denial of access to the web interface by repeatedly requesting the /accessdenied URL.","url":"https://insights.sbomify.com/CVE-2024-10511/"}