CVE-2024-10771 SICK InspectorP61x, SICK InspectorP62x and SICK TiM3xx are vulnerable for remote code execution

High 8.8 Published Updated

Attackers with Service-level network access can execute arbitrary root commands via missing input validation during firmware updates on SICK industrial devices.

Exploited in the wild
Not known
Login needed
Any signed-in user
Attackable
Over the internet
Victim action needed
Not needed
Fix
None listed

What is CVE-2024-10771?

CVE-2024-10771 is a high-severity code injection vulnerability in SICK InspectorP61x, published on 6 Dec 2024. Any signed-in user can exploit it over the network, with no action from the victim.

Official description

Due to missing input validation during one step of the firmware update process, the product is vulnerable to remote code execution. With network access and the user level ”Service”, an attacker can execute arbitrary system commands in the root user’s contexts.

Weakness: CWE-94

Which versions are affected by CVE-2024-10771?

How do I fix CVE-2024-10771?

No fix has been published for CVE-2024-10771 yet. Limit exposure of the affected software until one is available.

Upgrade, and never evaluate templates, expressions or code built from user input. More about Code injection.

Is CVE-2024-10771 being exploited?

There is no known exploitation of CVE-2024-10771 in the wild and no public exploit code.

Sources

Also known as GHSA-252q-qph8-r7q3.

Is CVE-2024-10771 in your software?