{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2024-1093 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2024-1093 yet. Limit exposure of the affected software until one is available.","what":"CVE-2024-1093 is a medium-severity missing authorization vulnerability in simon99 Change Memory Limit, published on 5 Mar 2024. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2024-1093 and fix it if it is affected.\n\nWhat it is: CVE-2024-1093 is a medium-severity missing authorization vulnerability in simon99 Change Memory Limit, published on 5 Mar 2024. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2024-1093 in the wild and no public exploit code.\n\nAffected product: simon99 Change Memory Limit. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2024-1093/ (Markdown: https://insights.sbomify.com/CVE-2024-1093/index.md)","id":"CVE-2024-1093","markdown":"https://insights.sbomify.com/CVE-2024-1093/index.md","name":"CVE-2024-1093","record":{"aliases":["GHSA-f9mp-9f6r-9536"],"analysis":{"component_type":"cms_plugin","fix_type":"patch","impacts":["data_modify"],"network_reachable":"yes","non_default_config":false,"product_category":"WordPress plugin","requires_auth":"none","summary":"Unauthenticated attackers can modify the memory limit setting due to a missing capability check in the admin_logic function.","user_interaction":"not_required","vuln_class":"missing_authorization"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"Wordfence","cpe":[{"product":"change_memory_limit","vendor":"simon99"}],"cvss":{"score":5.3,"severity":"medium","source":"cna","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N","version":"3.1"},"cwes":[{"id":"CWE-862","name":"Missing Authorization"}],"description":"The Change Memory Limit plugin for WordPress is vulnerable to unauthorized modification of data due to a missing capability check on the admin_logic() function hooked via admin_init in all versions up to, and including, 1.0. This makes it possible for unauthenticated attackers to update the memory limit.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Change Memory Limit \u003c= 1.0 - Missing Authorization via admin_logic()","id":"CVE-2024-1093","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"missing_authorization","year":"2024"},"n_packages":0,"n_references":2,"next":{"headline":"Missing authorization in Timetics – Appointment Booking \u0026 Scheduling","id":"CVE-2024-1094"},"packages":[],"prev":{"headline":"Missing authorization in RSS Aggregator by Feedzy – Feed to Post, Autoblogging, News \u0026 YouTube Video Feeds Aggregator","id":"CVE-2024-1092"},"products":["Change Memory Limit"],"published":"2024-03-05","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"partial"},"state":"PUBLISHED","updated":"2026-04-08","vendors":["simon99"]},"summary":"Unauthenticated attackers can modify the memory limit setting due to a missing capability check in the admin_logic function.","url":"https://insights.sbomify.com/CVE-2024-1093/"}