{"answers":{"affected":"","exploited":"There is no known exploitation of CVE-2024-11014 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2024-11014 yet. Limit exposure of the affected software until one is available.","what":"CVE-2024-11014 is a medium-severity vulnerability in NEC Corporation UNIVERGE IX, published on 29 Nov 2024. An attacker can exploit it over the internet without logging in, and only if a user opens a file or follows a link."},"fix_prompt":"Check this codebase for CVE-2024-11014 and fix it if it is affected.\n\nWhat it is: CVE-2024-11014 is a medium-severity vulnerability in NEC Corporation UNIVERGE IX, published on 29 Nov 2024. An attacker can exploit it over the internet without logging in, and only if a user opens a file or follows a link.\nExploitation: There is no known exploitation of CVE-2024-11014 in the wild and no public exploit code.\n\nAffected product: NEC Corporation UNIVERGE IX. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2024-11014/ (Markdown: https://insights.sbomify.com/CVE-2024-11014/index.md)","id":"CVE-2024-11014","markdown":"https://insights.sbomify.com/CVE-2024-11014/index.md","name":"CVE-2024-11014","record":{"aliases":["GHSA-xhf4-qqf8-2pw6"],"analysis":{"component_type":"network_device","fix_type":"upgrade","impacts":["account_takeover"],"network_reachable":"yes","non_default_config":false,"product_category":"NEC UNIVERGE IX router","requires_auth":"none","summary":"Attackers can hijack user sessions on the NEC UNIVERGE IX management interface via CSRF, potentially gaining unauthorized administrative access.","user_interaction":"required","vuln_class":"csrf"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"NEC","cpe":[],"cvss":{"score":4.3,"severity":"medium","source":"cna","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N","version":"3.1"},"cwes":[{"id":"CWE-352","name":"Cross-Site Request Forgery"}],"description":"Cross-site request forgery (CSRF) vulnerability in NEC Corporation UNIVERGE IX from Ver9.2 to Ver10.10.21, for Ver10.8 up to Ver10.8.27 and for Ver10.9 up to Ver10.9.14 allows a attacker to hijack the authentication of screens on the device via the management interface.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Cross-site request forgery in UNIVERGE IX","id":"CVE-2024-11014","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"csrf","year":"2024"},"n_packages":0,"n_references":1,"next":{"headline":"Sign In With Google \u003c= 1.8.0 - Authentication Bypass in authenticate_user","id":"CVE-2024-11015"},"packages":[],"prev":{"headline":"Command injection in UNIVERGE IX","id":"CVE-2024-11013"},"products":["UNIVERGE IX"],"published":"2024-11-29","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"partial"},"state":"PUBLISHED","updated":"2025-07-24","vendors":["NEC Corporation"]},"summary":"Attackers can hijack user sessions on the NEC UNIVERGE IX management interface via CSRF, potentially gaining unauthorized administrative access.","url":"https://insights.sbomify.com/CVE-2024-11014/"}