{"answers":{"affected":"It affects 3 products.","exploited":"It is not confirmed as exploited in the wild, but public exploit code for CVE-2024-11657 exists.","fix":"No fix has been published for CVE-2024-11657 yet. Limit exposure of the affected software until one is available.","what":"CVE-2024-11657 is a medium-severity command injection vulnerability in EnGenius ENH1350EXT, published on 25 Nov 2024. An attacker needs administrator access to exploit it, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2024-11657 and fix it if it is affected.\n\nWhat it is: CVE-2024-11657 is a medium-severity command injection vulnerability in EnGenius ENH1350EXT, published on 25 Nov 2024. An attacker needs administrator access to exploit it, with no action from the victim.\nExploitation: It is not confirmed as exploited in the wild, but public exploit code for CVE-2024-11657 exists.\n\nAffected product: EnGenius ENH1350EXT. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2024-11657/ (Markdown: https://insights.sbomify.com/CVE-2024-11657/index.md)","id":"CVE-2024-11657","markdown":"https://insights.sbomify.com/CVE-2024-11657/index.md","name":"CVE-2024-11657","record":{"aliases":["GHSA-c2mv-vx32-cw2p"],"analysis":{"component_type":"network_device","fix_type":"no_fix_stated","impacts":["code_execution"],"network_reachable":"yes","non_default_config":false,"product_category":"EnGenius access point","requires_auth":"high_privilege","summary":"Remote attackers can execute arbitrary commands on EnGenius access points via the diag_nslookup interface, requiring administrative privileges.","user_interaction":"not_required","vuln_class":"command_injection"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"VulDB","cpe":[{"product":"enh1350ext_firmware","vendor":"engeniustech"},{"product":"ens500-ac_firmware","vendor":"engeniustech"},{"product":"ens620ext_firmware","vendor":"engeniustech"}],"cvss":{"score":5.1,"severity":"medium","source":"cna","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N","version":"4.0"},"cwes":[{"id":"CWE-77","name":"Improper Neutralization of Special Elements used in a Command"},{"id":"CWE-74","name":"Improper Neutralization of Special Elements in Output Used by a Downstream Component"}],"description":"A vulnerability, which was classified as critical, was found in EnGenius ENH1350EXT, ENS500-AC and ENS620EXT up to 20241118. Affected is an unknown function of the file /admin/network/diag_nslookup. The manipulation of the argument diag_nslookup leads to command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"weaponised"},"has_fix":null,"headline":"EnGenius ENH1350EXT/ENS500-AC/ENS620EXT diag_nslookup command injection","id":"CVE-2024-11657","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"command_injection","year":"2024"},"n_packages":0,"n_references":4,"next":{"headline":"EnGenius ENH1350EXT/ENS500-AC/ENS620EXT ajax_getChannelList command injection","id":"CVE-2024-11658"},"packages":[],"prev":{"headline":"EnGenius ENH1350EXT/ENS500-AC/ENS620EXT diag_ping6 command injection","id":"CVE-2024-11656"},"products":["ENH1350EXT","ENS500-AC","ENS620EXT"],"published":"2024-11-25","related":[{"cvss_score":5.1,"headline":"EnGenius ENH1350EXT/ENS500-AC/ENS620EXT wifi_schedule command injection","id":"CVE-2024-11651","kev_date_added":null,"published":"2024-11-25"},{"cvss_score":5.1,"headline":"EnGenius ENH1350EXT/ENS500-AC/ENS620EXT sn_https command injection","id":"CVE-2024-11652","kev_date_added":null,"published":"2024-11-25"},{"cvss_score":5.1,"headline":"EnGenius ENH1350EXT/ENS500-AC/ENS620EXT diag_traceroute command injection","id":"CVE-2024-11653","kev_date_added":null,"published":"2024-11-25"},{"cvss_score":5.1,"headline":"EnGenius ENH1350EXT/ENS500-AC/ENS620EXT diag_traceroute6 command injection","id":"CVE-2024-11654","kev_date_added":null,"published":"2024-11-25"},{"cvss_score":5.1,"headline":"EnGenius ENH1350EXT/ENS500-AC/ENS620EXT diag_pinginterface command injection","id":"CVE-2024-11655","kev_date_added":null,"published":"2024-11-25"},{"cvss_score":5.1,"headline":"EnGenius ENH1350EXT/ENS500-AC/ENS620EXT diag_ping6 command injection","id":"CVE-2024-11656","kev_date_added":null,"published":"2024-11-25"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"poc","technical_impact":"partial"},"state":"PUBLISHED","updated":"2024-11-26","vendors":["EnGenius"]},"summary":"Remote attackers can execute arbitrary commands on EnGenius access points via the diag_nslookup interface, requiring administrative privileges.","url":"https://insights.sbomify.com/CVE-2024-11657/"}