{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2024-11666 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2024-11666 yet. Limit exposure of the affected software until one is available.","what":"CVE-2024-11666 is a critical command injection vulnerability in hardy-barth cph2_echarge_firmware, published on 24 Nov 2024. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2024-11666 and fix it if it is affected.\n\nWhat it is: CVE-2024-11666 is a critical command injection vulnerability in hardy-barth cph2_echarge_firmware, published on 24 Nov 2024. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2024-11666 in the wild and no public exploit code.\n\nAffected product: hardy-barth cph2_echarge_firmware. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2024-11666/ (Markdown: https://insights.sbomify.com/CVE-2024-11666/index.md)","id":"CVE-2024-11666","markdown":"https://insights.sbomify.com/CVE-2024-11666/index.md","name":"CVE-2024-11666","record":{"aliases":["GHSA-38x5-mx6x-v39w"],"analysis":{"component_type":"iot_embedded","fix_type":"upgrade","impacts":["code_execution","privilege_escalation"],"network_reachable":"yes","non_default_config":false,"product_category":"EV charger firmware","requires_auth":"none","summary":"Unauthenticated attackers can execute arbitrary commands with elevated privileges on EV chargers by intercepting insecure cloud communication.","user_interaction":"not_required","vuln_class":"command_injection"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"ONEKEY","cpe":[{"product":"salia_plcc_firmware","vendor":"echarge"}],"cvss":{"score":9,"severity":"critical","source":"cna","vector":"CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:C/C:H/I:H/A:H","version":"3.1"},"cwes":[{"id":"CWE-345","name":"Insufficient Verification of Data Authenticity"}],"description":"Affected devices beacon to eCharge cloud infrastructure asking if there are any command they should run. This communication is established over an insecure channel since peer verification is disabled everywhere. Therefore, remote unauthenticated users  suitably positioned on the network between an EV charger controller and eCharge infrastructure can execute arbitrary commands with elevated privileges on affected devices.\n\nThis issue affects cph2_echarge_firmware: through 2.0.4.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Unauthenticated Remote Command Injection in eCharge Salia PLCC","id":"CVE-2024-11666","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"command_injection","year":"2024"},"n_packages":0,"n_references":1,"next":{"headline":"Zyxel Multiple Firewalls Path Traversal","id":"CVE-2024-11667"},"packages":[],"prev":{"headline":"Unauthenticated Remote Command Injection","id":"CVE-2024-11665"},"products":["cph2_echarge_firmware"],"published":"2024-11-24","related":[{"cvss_score":8.8,"headline":"Unauthenticated Remote Command Injection","id":"CVE-2024-11665","kev_date_added":null,"published":"2024-11-24"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"total"},"state":"PUBLISHED","updated":"2024-11-25","vendors":["hardy-barth"]},"summary":"Unauthenticated attackers can execute arbitrary commands with elevated privileges on EV chargers by intercepting insecure cloud communication.","url":"https://insights.sbomify.com/CVE-2024-11666/"}