{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2024-1185 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2024-1185 yet. Limit exposure of the affected software until one is available.","what":"CVE-2024-1185 is a low-severity denial of service vulnerability in Nsasoft NBMonitor Network Bandwidth Monitor, published on 2 Feb 2024. It can only be exploited from the same machine or local network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2024-1185 and fix it if it is affected.\n\nWhat it is: CVE-2024-1185 is a low-severity denial of service vulnerability in Nsasoft NBMonitor Network Bandwidth Monitor, published on 2 Feb 2024. It can only be exploited from the same machine or local network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2024-1185 in the wild and no public exploit code.\n\nAffected product: Nsasoft NBMonitor Network Bandwidth Monitor. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2024-1185/ (Markdown: https://insights.sbomify.com/CVE-2024-1185/index.md)","id":"CVE-2024-1185","markdown":"https://insights.sbomify.com/CVE-2024-1185/index.md","name":"CVE-2024-1185","record":{"aliases":["GHSA-mmj5-4682-wjr2"],"analysis":{"component_type":"desktop_application","fix_type":"no_fix_stated","impacts":["denial_of_service"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"Network Bandwidth Monitor","requires_auth":"low_privilege","summary":"A local attacker can cause a denial of service in Nsasoft NBMonitor via the Registration Handler, requiring local access and permissions.","user_interaction":"not_required","vuln_class":"denial_of_service"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"VulDB","cpe":[{"product":"network_bandwidth_monitor","vendor":"nsasoft"}],"cvss":{"score":3.3,"severity":"low","source":"cna","vector":"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:L","version":"3.1"},"cwes":[{"id":"CWE-404","name":"Improper Resource Shutdown or Release"}],"description":"A vulnerability classified as problematic has been found in Nsasoft NBMonitor Network Bandwidth Monitor 1.6.5.0. This affects an unknown part of the component Registration Handler. The manipulation leads to denial of service. The attack needs to be approached locally. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-252675. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Nsasoft NBMonitor Network Bandwidth Monitor Registration denial of service","id":"CVE-2024-1185","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"denial_of_service","year":"2024"},"n_packages":0,"n_references":3,"next":{"headline":"Munsoft Easy Archive Recovery Registration Key denial of service","id":"CVE-2024-1186"},"packages":[],"prev":{"headline":"Nsasoft Network Sleuth Registration denial of service","id":"CVE-2024-1184"},"products":["NBMonitor Network Bandwidth Monitor"],"published":"2024-02-02","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"partial"},"state":"PUBLISHED","updated":"2024-08-01","vendors":["Nsasoft"]},"summary":"A local attacker can cause a denial of service in Nsasoft NBMonitor via the Registration Handler, requiring local access and permissions.","url":"https://insights.sbomify.com/CVE-2024-1185/"}