# CVE-2024-13502: A command injection in the NTC2218, NTC2250, NTC2299 modems' web interfaces allows to exeucte arbitrary shell commands.

> Attackers can execute arbitrary shell commands via the web interface of Newtec/iDirect satellite modems due to improper input handling.

- **Severity:** Critical 9.3 (`CVSS:4.0/AV:A/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H`)
- **Exploited in the wild:** Not known
- **Login needed:** An administrator
- **Attackable:** Local or same network only
- **Victim action needed:** Not needed
- **Fix available:** No
- **Published:** 17 Jan 2025
- **Updated:** 17 Jan 2025
- **Also known as:** GHSA-7jmp-6wfw-34gv

## What is CVE-2024-13502?

CVE-2024-13502 is a critical command injection vulnerability in Newtec/iDirect NTC2218, NTC2250, NTC2299, published on 17 Jan 2025. It can only be exploited from the same machine or local network, with no action from the victim.

### Official description

Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability in Newtec/iDirect NTC2218, NTC2250, NTC2299 on Linux, PowerPC, ARM allows Local Code Inclusion.This issue affects NTC2218, NTC2250, NTC2299: from 1.0.1.1 through 2.2.6.19.

The `commit_multicast` page used to configure multicasts in the modem's web administration interface uses improperly parses incoming data from the request before passing it to an `eval` statement in a bash script. This allows attackers to inject arbitrary shell commands.

Weakness: CWE-78 (Improper Neutralization of Special Elements used in an OS Command)

## Which versions are affected by CVE-2024-13502?


## How do I fix CVE-2024-13502?

No fix has been published for CVE-2024-13502 yet. Limit exposure of the affected software until one is available.

## Is CVE-2024-13502 being exploited?

There is no known exploitation of CVE-2024-13502 in the wild and no public exploit code.

## Fix prompt for AI coding agents

```text
Check this codebase for CVE-2024-13502 and fix it if it is affected.

What it is: CVE-2024-13502 is a critical command injection vulnerability in Newtec/iDirect NTC2218, NTC2250, NTC2299, published on 17 Jan 2025. It can only be exploited from the same machine or local network, with no action from the victim.
Exploitation: There is no known exploitation of CVE-2024-13502 in the wild and no public exploit code.

Affected product: Newtec/iDirect NTC2218, NTC2250, NTC2299. No package-level version data is available, so check the vendor advisory linked from the reference page.

Task:
1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.
2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.
3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.
4. Run the tests and summarise what changed and why.
5. If nothing in the project is affected, say so and change nothing.

Reference: https://insights.sbomify.com/CVE-2024-13502/ (Markdown: https://insights.sbomify.com/CVE-2024-13502/index.md)
```

## Sources

- CVE record: https://www.cve.org/CVERecord?id=CVE-2024-13502
- NVD: https://nvd.nist.gov/vuln/detail/CVE-2024-13502
- OSV: https://osv.dev/vulnerability/CVE-2024-13502

---
From sbomify Insights: https://insights.sbomify.com/CVE-2024-13502/