{"answers":{"affected":"","exploited":"There is no known exploitation of CVE-2024-14007 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2024-14007 yet. Limit exposure of the affected software until one is available.","what":"CVE-2024-14007 is a high-severity authentication bypass vulnerability in Shenzhen TVT Digital Technology Co., Ltd. NVMS-9000, published on 24 Nov 2025. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2024-14007 and fix it if it is affected.\n\nWhat it is: CVE-2024-14007 is a high-severity authentication bypass vulnerability in Shenzhen TVT Digital Technology Co., Ltd. NVMS-9000, published on 24 Nov 2025. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2024-14007 in the wild and no public exploit code.\n\nAffected product: Shenzhen TVT Digital Technology Co., Ltd. NVMS-9000. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2024-14007/ (Markdown: https://insights.sbomify.com/CVE-2024-14007/index.md)","id":"CVE-2024-14007","markdown":"https://insights.sbomify.com/CVE-2024-14007/index.md","name":"CVE-2024-14007","record":{"aliases":["GHSA-3qf4-5xvv-769w"],"analysis":{"component_type":"iot_embedded","fix_type":"upgrade","impacts":["data_read","security_bypass"],"network_reachable":"yes","non_default_config":false,"product_category":"DVR/NVR firmware","requires_auth":"none","summary":"Unauthenticated remote attackers can bypass authentication to retrieve sensitive configuration data and cleartext credentials from TVT NVMS-9000 devices.","user_interaction":"not_required","vuln_class":"auth_bypass"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"VulnCheck","cpe":[],"cvss":{"score":8.7,"severity":"high","source":"cna","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N","version":"4.0"},"cwes":[{"id":"CWE-306","name":"Missing Authentication for Critical Functionality"}],"description":"Shenzhen TVT Digital Technology Co., Ltd. NVMS-9000 firmware (used by many white-labeled DVR/NVR/IPC products) versions prior to 1.3.4 contain an authentication bypass in the NVMS-9000 control protocol. By sending a single crafted TCP payload to an exposed NVMS-9000 control port, an unauthenticated remote attacker can invoke privileged administrative query commands without valid credentials. Successful exploitation discloses sensitive information including administrator usernames and passwords in cleartext, network and service configuration, and other device details via commands such as queryBasicCfg, queryUserList, queryEmailCfg, queryPPPoECfg, and queryFTPCfg.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"TVT NVMS-9000 \u003c 1.3.4 Unauthenticated Administrative Queries \u0026 Information Disclosure","id":"CVE-2024-14007","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"auth_bypass","year":"2024"},"n_packages":0,"n_references":4,"next":{"headline":"Nagios XI \u003c 2024R1.3.2 RCE via WinRM Configuration Wizard","id":"CVE-2024-14008"},"packages":[],"prev":{"headline":"Nagios XI \u003c 2024R1.2.2 Host Header Injection","id":"CVE-2024-14006"},"products":["NVMS-9000"],"published":"2025-11-24","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"partial"},"state":"PUBLISHED","updated":"2025-11-25","vendors":["Shenzhen TVT Digital Technology Co., Ltd."]},"summary":"Unauthenticated remote attackers can bypass authentication to retrieve sensitive configuration data and cleartext credentials from TVT NVMS-9000 devices.","url":"https://insights.sbomify.com/CVE-2024-14007/"}