{"answers":{"affected":"","exploited":"There is no known exploitation of CVE-2024-14028 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2024-14028 yet. Limit exposure of the affected software until one is available.","what":"CVE-2024-14028 is a medium-severity use after free vulnerability in Softing smartLink HW-DP, published on 27 Mar 2026. An attacker can exploit it over the internet without logging in, and only if a user opens a file or follows a link."},"fix_prompt":"Check this codebase for CVE-2024-14028 and fix it if it is affected.\n\nWhat it is: CVE-2024-14028 is a medium-severity use after free vulnerability in Softing smartLink HW-DP, published on 27 Mar 2026. An attacker can exploit it over the internet without logging in, and only if a user opens a file or follows a link.\nExploitation: There is no known exploitation of CVE-2024-14028 in the wild and no public exploit code.\n\nAffected product: Softing smartLink HW-DP. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2024-14028/ (Markdown: https://insights.sbomify.com/CVE-2024-14028/index.md)","id":"CVE-2024-14028","markdown":"https://insights.sbomify.com/CVE-2024-14028/index.md","name":"CVE-2024-14028","record":{"aliases":["GHSA-6wvc-gg7r-g28h"],"analysis":{"component_type":"iot_embedded","fix_type":"upgrade","impacts":["denial_of_service"],"network_reachable":"yes","non_default_config":false,"product_category":"Industrial IoT gateway","requires_auth":"none","summary":"An attacker can cause a crash or denial of service in Softing smartLink devices via multiple implicit reads in parallel.","user_interaction":"required","vuln_class":"use_after_free"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"Softing","cpe":[],"cvss":{"score":6.5,"severity":"medium","source":"cna","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H","version":"3.1"},"cwes":[{"id":"CWE-416","name":"Use After Free"}],"description":"Use after free vulnerability in Softing smartLink HW-DP or smartLink HW-PN webserver allows HTTP DoS.\nThis issue affects:\nsmartLink HW-DP: through 1.31\nsmartLink HW-PN: before 1.02.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Multiple implicit reads in parallel can result in a crash or denial of service","id":"CVE-2024-14028","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"use_after_free","year":"2024"},"n_packages":0,"n_references":2,"next":{"headline":"Tornado before 6.4.1 HTTP Request Smuggling via Transfer-Encoding","id":"CVE-2024-14029"},"packages":[],"prev":{"headline":"xattr: switch to CLASS(fd)","id":"CVE-2024-14027"},"products":["smartLink HW-DP","smartLink HW-PN"],"published":"2026-03-27","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"partial"},"state":"PUBLISHED","updated":"2026-03-27","vendors":["Softing"]},"summary":"An attacker can cause a crash or denial of service in Softing smartLink devices via multiple implicit reads in parallel.","url":"https://insights.sbomify.com/CVE-2024-14028/"}