{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2024-1471 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2024-1471 yet. Limit exposure of the affected software until one is available.","what":"CVE-2024-1471 is a medium-severity cross-site scripting vulnerability in Tenable Security Center, published on 14 Feb 2024. An attacker needs administrator access to exploit it, and only if a user opens a file or follows a link."},"fix_prompt":"Check this codebase for CVE-2024-1471 and fix it if it is affected.\n\nWhat it is: CVE-2024-1471 is a medium-severity cross-site scripting vulnerability in Tenable Security Center, published on 14 Feb 2024. An attacker needs administrator access to exploit it, and only if a user opens a file or follows a link.\nExploitation: There is no known exploitation of CVE-2024-1471 in the wild and no public exploit code.\n\nAffected product: Tenable Security Center. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2024-1471/ (Markdown: https://insights.sbomify.com/CVE-2024-1471/index.md)","id":"CVE-2024-1471","markdown":"https://insights.sbomify.com/CVE-2024-1471/index.md","name":"CVE-2024-1471","record":{"aliases":["GHSA-9j55-g998-6v4p"],"analysis":{"component_type":"web_application","fix_type":"patch","impacts":["security_bypass"],"network_reachable":"yes","non_default_config":false,"product_category":"Tenable Security Center","requires_auth":"high_privilege","summary":"An authenticated administrator can inject HTML into repository parameters, enabling redirection attacks in Tenable Security Center.","user_interaction":"required","vuln_class":"xss"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"tenable","cpe":[{"product":"security_center","vendor":"tenable"}],"cvss":{"score":5.9,"severity":"medium","source":"cna","vector":"CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:L","version":"3.1"},"cwes":[{"id":"CWE-79","name":"Improper Neutralization of Input During Web Page Generation"},{"id":"CWE-20","name":"Improper Input Validation"}],"description":"An HTML injection vulnerability exists where an authenticated, remote attacker with administrator privileges on the Security Center application could modify Repository parameters, which could lead to HTML redirection attacks.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"HTML Injection Vulnerability","id":"CVE-2024-1471","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"xss","year":"2024"},"n_packages":0,"n_references":1,"next":{"headline":"WP Maintenance \u003c= 6.1.6 - Information Exposure","id":"CVE-2024-1472"},"packages":[],"prev":{"headline":"Elevation of Privilege attack on NetIQ Client login extension","id":"CVE-2024-1470"},"products":["Security Center"],"published":"2024-02-14","related":[{"cvss_score":9.4,"headline":"Remote Code Execution","id":"CVE-2026-19626","kev_date_added":null,"published":"2026-08-14"},{"cvss_score":9.4,"headline":"Command Injection","id":"CVE-2026-19681","kev_date_added":null,"published":"2026-08-14"},{"cvss_score":9.4,"headline":"Command Injection","id":"CVE-2026-19682","kev_date_added":null,"published":"2026-08-14"},{"cvss_score":9.4,"headline":"SQL injection in Security Center","id":"CVE-2026-64877","kev_date_added":null,"published":"2026-07-21"},{"cvss_score":9.4,"headline":"Command Injection","id":"CVE-2026-64878","kev_date_added":null,"published":"2026-07-21"},{"cvss_score":9.4,"headline":"Command Injection","id":"CVE-2026-64879","kev_date_added":null,"published":"2026-07-21"},{"cvss_score":8.8,"headline":"Information disclosure in SecurityCenter","id":"CVE-2018-1154","kev_date_added":null,"published":"2018-08-02"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"partial"},"state":"PUBLISHED","updated":"2024-08-01","vendors":["Tenable"]},"summary":"An authenticated administrator can inject HTML into repository parameters, enabling redirection attacks in Tenable Security Center.","url":"https://insights.sbomify.com/CVE-2024-1471/"}