{"answers":{"affected":"","exploited":"There is no known exploitation of CVE-2024-1573 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2024-1573 yet. Limit exposure of the affected software until one is available.","what":"CVE-2024-1573 is a medium-severity authentication bypass vulnerability in Mitsubishi Electric Corporation AnalytiX, published on 4 Jul 2024. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2024-1573 and fix it if it is affected.\n\nWhat it is: CVE-2024-1573 is a medium-severity authentication bypass vulnerability in Mitsubishi Electric Corporation AnalytiX, published on 4 Jul 2024. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2024-1573 in the wild and no public exploit code.\n\nAffected product: Mitsubishi Electric Corporation AnalytiX. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2024-1573/ (Markdown: https://insights.sbomify.com/CVE-2024-1573/index.md)","id":"CVE-2024-1573","markdown":"https://insights.sbomify.com/CVE-2024-1573/index.md","name":"CVE-2024-1573","record":{"aliases":["GHSA-34qf-4246-phgf"],"analysis":{"component_type":"ics_ot","fix_type":"patch","impacts":["security_bypass","account_takeover"],"network_reachable":"yes","non_default_config":true,"product_category":"SCADA monitoring software","requires_auth":"none","summary":"Remote attackers can bypass authentication in Mitsubishi Electric SCADA systems if specific Active Directory and IIS configurations are enabled.","user_interaction":"not_required","vuln_class":"auth_bypass"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"Mitsubishi","cpe":[],"cvss":{"score":5.9,"severity":"medium","source":"cna","vector":"CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:H/A:N","version":"3.1"},"cwes":[{"id":"CWE-306","name":"Missing Authentication for Critical Functionality"}],"description":"Missing Authentication for Critical Function vulnerability in the mobile monitoring feature of Mitsubishi Electric GENESIS64 versions 10.97.2 and prior, Mitsubishi Electric ICONICS Suite versions 10.97.2 and prior, Mitsubishi Electric Hyper Historian versions 10.97.2 and prior, Mitsubishi Electric AnalytiX versions 10.97.2 and prior, Mitsubishi Electric MobileHMI versions 10.97.2 and prior, Mitsubishi Electric IoTWorX version 10.95, Mitsubishi Electric MC Works64 all versions, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions Hyper Historian versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions AnalytiX versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions MobileHMI versions 10.97.2 and prior, and Mitsubishi Electric Iconics Digital Solutions IoTWorX version 10.95 allows a remote unauthenticated attacker to bypass proper authentication and log in to the system when all of the following conditions are met: (1) Active Directory is used in the security setting (2) \"Automatic log in\" option is enabled in the security setting (3) The IcoAnyGlass IIS Application Pool is running under an Active Directory Domain Account. (4) The IcoAnyGlass IIS Application Pool account is included in GENESIS64, ICONCIS Suite, and MC Works64 Security and has permission to log in.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Auth bypass in AnalytiX","id":"CVE-2024-1573","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"auth_bypass","year":"2024"},"n_packages":0,"n_references":3,"next":{"headline":"Code injection in AnalytiX","id":"CVE-2024-1574"},"packages":[],"prev":{"headline":"WP ULike \u003c= 4.6.9 - Authenticated (Contributor+) Stored Cross-Site Scripting via Shortcode","id":"CVE-2024-1572"},"products":["AnalytiX","GENESIS64","Hyper Historian","ICONICS Suite","IoTWorX","MC Works64","MobileHMI"],"published":"2024-07-04","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"total"},"state":"PUBLISHED","updated":"2026-04-13","vendors":["Mitsubishi Electric Corporation","Mitsubishi Electric Iconics Digital Solutions"]},"summary":"Remote attackers can bypass authentication in Mitsubishi Electric SCADA systems if specific Active Directory and IIS configurations are enabled.","url":"https://insights.sbomify.com/CVE-2024-1573/"}