{"answers":{"affected":"","exploited":"There is no known exploitation of CVE-2024-1629 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2024-1629 yet. Limit exposure of the affected software until one is available.","what":"CVE-2024-1629 is a medium-severity path traversal vulnerability in GE HealthCare LOGIQ E10, published on 14 May 2024. It can only be exploited from the same machine or local network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2024-1629 and fix it if it is affected.\n\nWhat it is: CVE-2024-1629 is a medium-severity path traversal vulnerability in GE HealthCare LOGIQ E10, published on 14 May 2024. It can only be exploited from the same machine or local network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2024-1629 in the wild and no public exploit code.\n\nAffected product: GE HealthCare LOGIQ E10. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2024-1629/ (Markdown: https://insights.sbomify.com/CVE-2024-1629/index.md)","id":"CVE-2024-1629","markdown":"https://insights.sbomify.com/CVE-2024-1629/index.md","name":"CVE-2024-1629","record":{"aliases":["GHSA-425c-w8px-7q9c"],"analysis":{"component_type":"iot_embedded","fix_type":"patch","impacts":["data_modify"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"GE HealthCare ultrasound","requires_auth":"none","summary":"An attacker can exploit a path traversal flaw in the deleteFiles function to modify or delete arbitrary files on GE HealthCare ultrasound devices.","user_interaction":"not_required","vuln_class":"path_traversal"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"GEHC","cpe":[],"cvss":{"score":6.2,"severity":"medium","source":"cna","vector":"CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N","version":"3.1"},"cwes":[{"id":"CWE-22","name":"Improper Limitation of a Pathname to a Restricted Directory"}],"description":"Path traversal vulnerability in “deleteFiles” function of Common Service Desktop, a GE HealthCare ultrasound device component","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Path traversal in LOGIQ E10","id":"CVE-2024-1629","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"path_traversal","year":"2024"},"n_packages":0,"n_references":1,"next":{"headline":"Path traversal in LOGIQ E10","id":"CVE-2024-1630"},"packages":[],"prev":{"headline":"OS command injection vulnerabilities in GE HealthCare ultrasound devices","id":"CVE-2024-1628"},"products":["LOGIQ E10","LOGIQ E10s","LOGIQ Fortis","LOGIQ He","LOGIQ e","Venue","Venue Fit","Venue Go","Vivid E","Vivid S","Vivid T","Vivid iq","Voluson Expert 16","Voluson Expert 18","Voluson Expert 22","Voluson SWIFT"],"published":"2024-05-14","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"partial"},"state":"PUBLISHED","updated":"2024-08-01","vendors":["GE HealthCare"]},"summary":"An attacker can exploit a path traversal flaw in the deleteFiles function to modify or delete arbitrary files on GE HealthCare ultrasound devices.","url":"https://insights.sbomify.com/CVE-2024-1629/"}