{"answers":{"affected":"","exploited":"It is not confirmed as exploited in the wild, but public exploit code for CVE-2024-1630 exists.","fix":"No fix has been published for CVE-2024-1630 yet. Limit exposure of the affected software until one is available.","what":"CVE-2024-1630 is a high-severity path traversal vulnerability in GE HealthCare LOGIQ E10, published on 14 May 2024. It can only be exploited from the same machine or local network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2024-1630 and fix it if it is affected.\n\nWhat it is: CVE-2024-1630 is a high-severity path traversal vulnerability in GE HealthCare LOGIQ E10, published on 14 May 2024. It can only be exploited from the same machine or local network, with no action from the victim.\nExploitation: It is not confirmed as exploited in the wild, but public exploit code for CVE-2024-1630 exists.\n\nAffected product: GE HealthCare LOGIQ E10. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2024-1630/ (Markdown: https://insights.sbomify.com/CVE-2024-1630/index.md)","id":"CVE-2024-1630","markdown":"https://insights.sbomify.com/CVE-2024-1630/index.md","name":"CVE-2024-1630","record":{"aliases":["GHSA-gwj2-vqgr-4qxf"],"analysis":{"component_type":"iot_embedded","fix_type":"patch","impacts":["data_read"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"GE HealthCare ultrasound","requires_auth":"none","summary":"An attacker can exploit a path traversal flaw in GE HealthCare ultrasound devices to read arbitrary files from the system.","user_interaction":"not_required","vuln_class":"path_traversal"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"GEHC","cpe":[],"cvss":{"score":7.7,"severity":"high","source":"cna","vector":"CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N","version":"3.1"},"cwes":[{"id":"CWE-22","name":"Improper Limitation of a Pathname to a Restricted Directory"}],"description":"Path traversal vulnerability in “getAllFolderContents” function of Common Service Desktop, a GE HealthCare ultrasound device component","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"weaponised"},"has_fix":null,"headline":"Path traversal in LOGIQ E10","id":"CVE-2024-1630","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"path_traversal","year":"2024"},"n_packages":0,"n_references":1,"next":{"headline":"agent-js: Insecure Key Generation in `Ed25519KeyIdentity.generate`","id":"CVE-2024-1631"},"packages":[],"prev":{"headline":"Path traversal in LOGIQ E10","id":"CVE-2024-1629"},"products":["LOGIQ E10","LOGIQ E10s","LOGIQ Fortis","LOGIQ He","LOGIQ e","Venue","Venue Fit","Venue Go","Vivid E","Vivid T","Vivid iq","Voluson Expert 16","Voluson Expert 18","Voluson Expert 22","Voluson SWIFT"],"published":"2024-05-14","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"poc","technical_impact":"total"},"state":"PUBLISHED","updated":"2024-08-22","vendors":["GE HealthCare"]},"summary":"An attacker can exploit a path traversal flaw in GE HealthCare ultrasound devices to read arbitrary files from the system.","url":"https://insights.sbomify.com/CVE-2024-1630/"}