{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2024-20906 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2024-20906 yet. Limit exposure of the affected software until one is available.","what":"CVE-2024-20906 is a medium-severity missing authorization vulnerability in Oracle Corporation SSM - (hot-tamale) ILOM: Integrated Lights Out Manager, published on 16 Jan 2024. An attacker needs administrator access to exploit it, and only if a user opens a file or follows a link."},"fix_prompt":"Check this codebase for CVE-2024-20906 and fix it if it is affected.\n\nWhat it is: CVE-2024-20906 is a medium-severity missing authorization vulnerability in Oracle Corporation SSM - (hot-tamale) ILOM: Integrated Lights Out Manager, published on 16 Jan 2024. An attacker needs administrator access to exploit it, and only if a user opens a file or follows a link.\nExploitation: There is no known exploitation of CVE-2024-20906 in the wild and no public exploit code.\n\nAffected product: Oracle Corporation SSM - (hot-tamale) ILOM: Integrated Lights Out Manager. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2024-20906/ (Markdown: https://insights.sbomify.com/CVE-2024-20906/index.md)","id":"CVE-2024-20906","markdown":"https://insights.sbomify.com/CVE-2024-20906/index.md","name":"CVE-2024-20906","record":{"aliases":["GHSA-jj54-m9rr-8gjf"],"analysis":{"component_type":"hardware_firmware","fix_type":"patch","impacts":["data_read","data_modify"],"network_reachable":"yes","non_default_config":false,"product_category":"Oracle ILOM","requires_auth":"high_privilege","summary":"High-privileged attackers can modify and read ILOM data via ICMP, requiring user interaction and impacting additional products.","user_interaction":"required","vuln_class":"missing_authorization"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"oracle","cpe":[{"product":"integrated_lights_out_manager_firmware","vendor":"oracle"}],"cvss":{"score":4.8,"severity":"medium","source":"cna","vector":"CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N","version":"3.1"},"cwes":[],"description":"Vulnerability in the Integrated Lights Out Manager (ILOM) product of Oracle Systems (component: System Management).  Supported versions that are affected are 3, 4 and  5. Easily exploitable vulnerability allows high privileged attacker with network access via ICMP to compromise Integrated Lights Out Manager (ILOM).  Successful attacks require human interaction from a person other than the attacker and while the vulnerability is in Integrated Lights Out Manager (ILOM), attacks may significantly impact additional products (scope change). Successful attacks of this vulnerability can result in  unauthorized update, insert or delete access to some of Integrated Lights Out Manager (ILOM) accessible data as well as  unauthorized read access to a subset of Integrated Lights Out Manager (ILOM) accessible data. CVSS 3.1 Base Score 4.8 (Confidentiality and Integrity impacts).  CVSS Vector: (CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N).","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Missing authorization in SSM - (hot-tamale) ILOM: Integrated Lights Out Manager","id":"CVE-2024-20906","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"missing_authorization","year":"2024"},"n_packages":0,"n_references":1,"next":{"headline":"Other in Web Applications Desktop Integrator","id":"CVE-2024-20907"},"packages":[],"prev":{"headline":"Denial of service in JD Edwards EnterpriseOne Tools","id":"CVE-2024-20905"},"products":["SSM - (hot-tamale) ILOM: Integrated Lights Out Manager"],"published":"2024-01-16","related":[{"cvss_score":9.8,"headline":"Other in n/a","id":"CVE-2016-5453","kev_date_added":null,"published":"2016-07-21"},{"cvss_score":8.8,"headline":"Other in n/a","id":"CVE-2016-5457","kev_date_added":null,"published":"2016-07-21"},{"cvss_score":8.3,"headline":"Other in n/a","id":"CVE-2016-5445","kev_date_added":null,"published":"2016-07-21"},{"cvss_score":7.7,"headline":"Missing authorization in SSM - (hot-tamale) ILOM: Integrated Lights Out Manager","id":"CVE-2018-2566","kev_date_added":null,"published":"2018-01-18"},{"cvss_score":7.7,"headline":"Denial of service in n/a","id":"CVE-2016-3481","kev_date_added":null,"published":"2016-07-21"},{"cvss_score":7.6,"headline":"Other in n/a","id":"CVE-2016-5447","kev_date_added":null,"published":"2016-07-21"},{"cvss_score":7.5,"headline":"Vulnerability in the Oracle Integrated Lights Out Manager (ILOM) component of Oracle Sun Systems Products Suite (subcomponent: System Management).","id":"CVE-2017-10260","kev_date_added":null,"published":"2017-10-19"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"partial"},"state":"PUBLISHED","updated":"2025-06-06","vendors":["Oracle Corporation"]},"summary":"High-privileged attackers can modify and read ILOM data via ICMP, requiring user interaction and impacting additional products.","url":"https://insights.sbomify.com/CVE-2024-20906/"}