{"answers":{"affected":"","exploited":"There is no known exploitation of CVE-2024-2103 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2024-2103 yet. Limit exposure of the affected software until one is available.","what":"CVE-2024-2103 is a medium-severity vulnerability in SEL-710-5 Motor Protection Relay  SEL-700G Generator Protection Relay, published on 4 Apr 2024. An attacker needs administrator access to exploit it, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2024-2103 and fix it if it is affected.\n\nWhat it is: CVE-2024-2103 is a medium-severity vulnerability in SEL-710-5 Motor Protection Relay  SEL-700G Generator Protection Relay, published on 4 Apr 2024. An attacker needs administrator access to exploit it, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2024-2103 in the wild and no public exploit code.\n\nAffected product: SEL-710-5 Motor Protection Relay  SEL-700G Generator Protection Relay. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2024-2103/ (Markdown: https://insights.sbomify.com/CVE-2024-2103/index.md)","id":"CVE-2024-2103","markdown":"https://insights.sbomify.com/CVE-2024-2103/index.md","name":"CVE-2024-2103","record":{"aliases":["GHSA-r596-ggc2-8m6g"],"analysis":{"component_type":"ics_ot","fix_type":"no_fix_stated","impacts":["other"],"network_reachable":"yes","non_default_config":false,"product_category":"SEL protection relays","requires_auth":"high_privilege","summary":"Undocumented features in SEL relays may cause unpredictable behavior when accessed by privileged users, requiring attention from industrial control system operators.","user_interaction":"not_required","vuln_class":"other"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"SEL","cpe":[],"cvss":{"score":6.5,"severity":"medium","source":"cna","vector":"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:H/A:H","version":"3.1"},"cwes":[{"id":"CWE-1242","name":"Inclusion of Undocumented Features or Chicken Bits"}],"description":"Inclusion of undocumented features vulnerability accessible when logged on with a privileged access level on the following Schweitzer Engineering Laboratories relays could allow the relay to behave unpredictably:\nSEL-700BT Motor Bus Transfer Relay, SEL-700G Generator Protection Relay, SEL-710-5 Motor Protection Relay, SEL-751 Feeder Protection Relay, SEL-787-2/-3/-4 Transformer Protection Relay, SEL-787Z High-Impedance Differential Relay\n\n. See product instruction manual appendix A dated 20240308 for more details regarding the SEL-751 Feeder Protection Relay. For more information for the other affected products, see their instruction manuals dated 20240329.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Inclusion of Undocumented Features","id":"CVE-2024-2103","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"other","year":"2024"},"n_packages":0,"n_references":1,"next":{"headline":"JBL: Improper BLE security configurations and lack of authentication on the device's GATT server","id":"CVE-2024-2104"},"packages":[],"prev":{"headline":"Salon booking system \u003c 9.6.3 - Unauthenticated Stored XSS","id":"CVE-2024-2102"},"products":[" SEL-700G Generator Protection Relay","SEL-700BT Motor Bus Transfer Relay","SEL-710-5 Motor Protection Relay","SEL-751 Feeder Protection Relay","SEL-787-2/-3/-4 Transformer Protection Relay","SEL-787Z High-Impedance Differential Relay"],"published":"2024-04-04","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"partial"},"state":"PUBLISHED","updated":"2024-08-01","vendors":["SEL-710-5 Motor Protection Relay","Schweitzer Engineering Laboratories"]},"summary":"Undocumented features in SEL relays may cause unpredictable behavior when accessed by privileged users, requiring attention from industrial control system operators.","url":"https://insights.sbomify.com/CVE-2024-2103/"}