{"answers":{"affected":"","exploited":"There is no known exploitation of CVE-2024-21483 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2024-21483 yet. Limit exposure of the affected software until one is available.","what":"CVE-2024-21483 is a medium-severity vulnerability in Siemens SENTRON 7KM PAC3120 AC/DC, published on 12 Mar 2024. It can only be exploited from the same machine or local network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2024-21483 and fix it if it is affected.\n\nWhat it is: CVE-2024-21483 is a medium-severity vulnerability in Siemens SENTRON 7KM PAC3120 AC/DC, published on 12 Mar 2024. It can only be exploited from the same machine or local network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2024-21483 in the wild and no public exploit code.\n\nAffected product: Siemens SENTRON 7KM PAC3120 AC/DC. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2024-21483/ (Markdown: https://insights.sbomify.com/CVE-2024-21483/index.md)","id":"CVE-2024-21483","markdown":"https://insights.sbomify.com/CVE-2024-21483/index.md","name":"CVE-2024-21483","record":{"aliases":["GHSA-cc9x-2646-xv35"],"analysis":{"component_type":"ics_ot","fix_type":"upgrade","impacts":["data_read"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"Siemens power meter","requires_auth":"none","summary":"An attacker with physical access can read internal flash data due to missing read-out protection during manufacturing.","user_interaction":"not_required","vuln_class":"information_disclosure"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"siemens","cpe":[],"cvss":{"score":5.1,"severity":"medium","source":"cna","vector":"CVSS:4.0/AV:P/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N","version":"4.0"},"cwes":[{"id":"CWE-284","name":"Improper Access Control"}],"description":"A vulnerability has been identified in SENTRON 7KM PAC3120 AC/DC (7KM3120-0BA01-1DA0) (All versions \u003e= V3.2.3 \u003c V3.2.4 only when manufactured between LQN231003... and LQN231215... ( with LQNYYMMDD...)), SENTRON 7KM PAC3120 DC (7KM3120-1BA01-1EA0) (All versions \u003e= V3.2.3 \u003c V3.2.4 only when manufactured between LQN231003... and LQN231215... ( with LQNYYMMDD...)), SENTRON 7KM PAC3220 AC/DC (7KM3220-0BA01-1DA0) (All versions \u003e= V3.2.3 \u003c V3.2.4 only when manufactured between LQN231003... and LQN231215... ( with LQNYYMMDD...)), SENTRON 7KM PAC3220 DC (7KM3220-1BA01-1EA0) (All versions \u003e= V3.2.3 \u003c V3.2.4 only when manufactured between LQN231003... and LQN231215... ( with LQNYYMMDD...)). The read out protection of the internal flash of affected devices was not properly set at the end of the manufacturing process.\r\n\r\nAn attacker with physical access to the device could read out the data.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Information disclosure in SENTRON 7KM PAC3120 AC/DC","id":"CVE-2024-21483","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"information_disclosure","year":"2024"},"n_packages":0,"n_references":1,"next":{"headline":"Marvin Attack of RSA and RSAOAEP decryption in jsrsasign","id":"CVE-2024-21484"},"packages":[],"prev":{"headline":"Improper Restriction of Operations within the Bounds of a Memory Buffer in Linux Boot Loader","id":"CVE-2024-21482"},"products":["SENTRON 7KM PAC3120 AC/DC","SENTRON 7KM PAC3120 DC","SENTRON 7KM PAC3220 AC/DC","SENTRON 7KM PAC3220 DC"],"published":"2024-03-12","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"partial"},"state":"PUBLISHED","updated":"2025-04-15","vendors":["Siemens"]},"summary":"An attacker with physical access can read internal flash data due to missing read-out protection during manufacturing.","url":"https://insights.sbomify.com/CVE-2024-21483/"}