{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2024-21794 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2024-21794 yet. Limit exposure of the affected software until one is available.","what":"CVE-2024-21794 is a medium-severity vulnerability in Rapid SCADA, published on 1 Feb 2024. Any signed-in user can exploit it over the network, and only if a user opens a file or follows a link."},"fix_prompt":"Check this codebase for CVE-2024-21794 and fix it if it is affected.\n\nWhat it is: CVE-2024-21794 is a medium-severity vulnerability in Rapid SCADA, published on 1 Feb 2024. Any signed-in user can exploit it over the network, and only if a user opens a file or follows a link.\nExploitation: There is no known exploitation of CVE-2024-21794 in the wild and no public exploit code.\n\nAffected product: Rapid SCADA. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2024-21794/ (Markdown: https://insights.sbomify.com/CVE-2024-21794/index.md)","id":"CVE-2024-21794","markdown":"https://insights.sbomify.com/CVE-2024-21794/index.md","name":"CVE-2024-21794","record":{"aliases":["GHSA-936g-qj35-5658"],"analysis":{"component_type":"ics_ot","fix_type":"upgrade","impacts":["security_bypass"],"network_reachable":"yes","non_default_config":false,"product_category":"Rapid SCADA","requires_auth":"low_privilege","summary":"An attacker can redirect users to malicious pages via the login page in Rapid SCADA, potentially facilitating phishing attacks.","user_interaction":"required","vuln_class":"open_redirect"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"icscert","cpe":[{"product":"rapid_scada","vendor":"rapidscada"}],"cvss":{"score":5.4,"severity":"medium","source":"cna","vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:N/I:L/A:L","version":"3.1"},"cwes":[{"id":"CWE-601","name":"URL Redirection to Untrusted Site"}],"description":"In Rapid Software LLC's Rapid SCADA versions prior to Version 5.8.4, an attacker can redirect users to malicious pages through the login page.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Open Redirect in Rapid SCADA","id":"CVE-2024-21794","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"open_redirect","year":"2024"},"n_packages":0,"n_references":2,"next":{"headline":"Memory corruption in libbiosig","id":"CVE-2024-21795"},"packages":[],"prev":{"headline":"BIG-IP Central Manager OData Injection Vulnerability","id":"CVE-2024-21793"},"products":["Rapid SCADA"],"published":"2024-02-01","related":[{"cvss_score":9.8,"headline":"Use of Hard-Coded Credentials in Rapid SCADA","id":"CVE-2024-21764","kev_date_added":null,"published":"2024-02-01"},{"cvss_score":8.8,"headline":"Rapid SCADA Path Traversal","id":"CVE-2024-21852","kev_date_added":null,"published":"2024-02-01"},{"cvss_score":7.8,"headline":"Incorrect Permission Assignment for Critical Resource in Rapid SCADA","id":"CVE-2024-22016","kev_date_added":null,"published":"2024-02-01"},{"cvss_score":7.8,"headline":"Privilege escalation in n/a","id":"CVE-2020-22722","kev_date_added":null,"published":"2020-08-14"},{"cvss_score":7.8,"headline":"Privilege escalation in n/a","id":"CVE-2018-5313","kev_date_added":null,"published":"2018-03-08"},{"cvss_score":7.5,"headline":"Auth bypass in n/a","id":"CVE-2024-47221","kev_date_added":null,"published":"2024-09-22"},{"cvss_score":6.5,"headline":"Relative Path Traversal in Rapid SCADA","id":"CVE-2024-22096","kev_date_added":null,"published":"2024-02-01"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"total"},"state":"PUBLISHED","updated":"2025-06-16","vendors":["Rapid Software LLC"]},"summary":"An attacker can redirect users to malicious pages via the login page in Rapid SCADA, potentially facilitating phishing attacks.","url":"https://insights.sbomify.com/CVE-2024-21794/"}