{"answers":{"affected":"","exploited":"There is no known exploitation of CVE-2024-22387 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2024-22387 yet. Limit exposure of the affected software until one is available.","what":"CVE-2024-22387 is a medium-severity missing authorization vulnerability in Gallagher Controller 6000 and Controller 7000, published on 11 Jul 2024. An attacker can exploit it over the internet without logging in, and only if a user opens a file or follows a link."},"fix_prompt":"Check this codebase for CVE-2024-22387 and fix it if it is affected.\n\nWhat it is: CVE-2024-22387 is a medium-severity missing authorization vulnerability in Gallagher Controller 6000 and Controller 7000, published on 11 Jul 2024. An attacker can exploit it over the internet without logging in, and only if a user opens a file or follows a link.\nExploitation: There is no known exploitation of CVE-2024-22387 in the wild and no public exploit code.\n\nAffected product: Gallagher Controller 6000 and Controller 7000. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2024-22387/ (Markdown: https://insights.sbomify.com/CVE-2024-22387/index.md)","id":"CVE-2024-22387","markdown":"https://insights.sbomify.com/CVE-2024-22387/index.md","name":"CVE-2024-22387","record":{"aliases":["GHSA-wq95-4r5j-p4x4"],"analysis":{"component_type":"ics_ot","fix_type":"configuration_change","impacts":["data_modify","security_bypass"],"network_reachable":"yes","non_default_config":true,"product_category":"Gallagher access controller","requires_auth":"none","summary":"Authenticated users can modify device I/O connections via the diagnostic web interface, potentially compromising physical security controls.","user_interaction":"required","vuln_class":"missing_authorization"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"Gallagher","cpe":[],"cvss":{"score":6.8,"severity":"medium","source":"cna","vector":"CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:N/I:H/A:H","version":"3.1"},"cwes":[{"id":"CWE-642","name":"External Control of Critical State Data"}],"description":"External Control of Critical State Data (CWE-642) in the Controller 6000 and Controller 7000 diagnostic web interface allows an authenticated user to modify device I/O connections leading to unexpected behavior that in some circumstances could compromise site physical security controls. Gallagher recommend the diagnostic web page is not enabled (default is off) unless advised by Gallagher Technical support. This interface is intended only for diagnostic purposes.\n\nThis issue affects: Gallagher Controller 6000 and 7000 \n\n9.10 prior to vCR9.10.240520a (distributed in 9.10.1268(MR1)), 9.00 prior to vCR9.00.240521a (distributed in 9.00.1990(MR3)), 8.90 prior to vCR8.90.240520a (distributed in 8.90.1947 (MR4)), 8.80 prior to vCR8.80.240520a (distributed in 8.80.1726 (MR5)), 8.70 prior to vCR8.70.240520a (distributed in 8.70.2824 (MR7)), all versions of 8.60 and prior.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Missing authorization in Controller 6000 and Controller 7000","id":"CVE-2024-22387","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"missing_authorization","year":"2024"},"n_packages":0,"n_references":1,"next":{"headline":"Insecure Default Initialization of Resource in HID Global","id":"CVE-2024-22388"},"packages":[],"prev":{"headline":"Race condition vulnerability in Linux kernel drm/exynos exynos_drm_crtc_atomic_disable","id":"CVE-2024-22386"},"products":["Controller 6000 and Controller 7000"],"published":"2024-07-11","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"partial"},"state":"PUBLISHED","updated":"2024-08-01","vendors":["Gallagher"]},"summary":"Authenticated users can modify device I/O connections via the diagnostic web interface, potentially compromising physical security controls.","url":"https://insights.sbomify.com/CVE-2024-22387/"}