{"answers":{"affected":"","exploited":"There is no known exploitation of CVE-2024-23485 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2024-23485 yet. Limit exposure of the affected software until one is available.","what":"CVE-2024-23485 is a medium-severity vulnerability in Gallagher Controller 6000 and Controller 7000, published on 11 Jul 2024. It can only be exploited from the same machine or local network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2024-23485 and fix it if it is affected.\n\nWhat it is: CVE-2024-23485 is a medium-severity vulnerability in Gallagher Controller 6000 and Controller 7000, published on 11 Jul 2024. It can only be exploited from the same machine or local network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2024-23485 in the wild and no public exploit code.\n\nAffected product: Gallagher Controller 6000 and Controller 7000. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2024-23485/ (Markdown: https://insights.sbomify.com/CVE-2024-23485/index.md)","id":"CVE-2024-23485","markdown":"https://insights.sbomify.com/CVE-2024-23485/index.md","name":"CVE-2024-23485","record":{"aliases":["GHSA-gwpc-v2jm-gv2g"],"analysis":{"component_type":"ics_ot","fix_type":"patch","impacts":["security_bypass"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"Physical access controller","requires_auth":"none","summary":"Attackers can bypass door lock security by exploiting a hardware state integrity flaw during power save operations in Gallagher controllers.","user_interaction":"not_required","vuln_class":"security_feature_bypass"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"Gallagher","cpe":[],"cvss":{"score":4.6,"severity":"medium","source":"cna","vector":"CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N","version":"3.1"},"cwes":[{"id":"CWE-1304","name":"Improperly Preserved Integrity of Hardware Configuration State During a Power Save/Restore Operation"}],"description":"Improperly Preserved Integrity of Hardware Configuration State During a Power Save/Restore Operation (CWE-1304) in the Controller 6000 and 7000 can lead to secured door locks connected via Aperio Communication Hubs to momentarily allow free access. \n\nThis issue affects: Gallagher Controller 6000 and 7000 9.10 prior to vCR9.10.240520a (distributed in 9.10.1268(MR1)), 9.00 prior to vCR9.00.240521a (distributed in 9.00.1990(MR3)),  8.90 prior to vCR8.90.240520a (distributed in 8.90.1947 (MR4)), 8.80 prior to vCR8.80.240520a (distributed in 8.80.1726 (MR5)), 8.70 prior to vCR8.70.240520a (distributed in 8.70.2824 (MR7)), all versions of 8.60 and prior.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Security feature bypass in Controller 6000 and Controller 7000","id":"CVE-2024-23485","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"security_feature_bypass","year":"2024"},"n_packages":0,"n_references":1,"next":{"headline":"Information disclosure in WSR-2533DHP","id":"CVE-2024-23486"},"packages":[],"prev":{"headline":"Local Privilege Escalation via lack of input validation","id":"CVE-2024-23483"},"products":["Controller 6000 and Controller 7000"],"published":"2024-07-11","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"partial"},"state":"PUBLISHED","updated":"2024-08-01","vendors":["Gallagher"]},"summary":"Attackers can bypass door lock security by exploiting a hardware state integrity flaw during power save operations in Gallagher controllers.","url":"https://insights.sbomify.com/CVE-2024-23485/"}