{"answers":{"affected":"","exploited":"It is not confirmed as exploited in the wild, but public exploit code for CVE-2024-2442 exists.","fix":"No fix has been published for CVE-2024-2442 yet. Limit exposure of the affected software until one is available.","what":"CVE-2024-2442 is a high-severity path traversal vulnerability in Franklin Fueling System EVO 5000, published on 19 Mar 2024. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2024-2442 and fix it if it is affected.\n\nWhat it is: CVE-2024-2442 is a high-severity path traversal vulnerability in Franklin Fueling System EVO 5000, published on 19 Mar 2024. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: It is not confirmed as exploited in the wild, but public exploit code for CVE-2024-2442 exists.\n\nAffected product: Franklin Fueling System EVO 5000. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2024-2442/ (Markdown: https://insights.sbomify.com/CVE-2024-2442/index.md)","id":"CVE-2024-2442","markdown":"https://insights.sbomify.com/CVE-2024-2442/index.md","name":"CVE-2024-2442","record":{"aliases":["GHSA-cxcr-v85c-3586"],"analysis":{"component_type":"ics_ot","fix_type":"no_fix_stated","impacts":["data_read"],"network_reachable":"yes","non_default_config":false,"product_category":"Fueling system controller","requires_auth":"none","summary":"An attacker can exploit a path traversal flaw in Franklin Fueling System EVO controllers to access sensitive files on the device.","user_interaction":"not_required","vuln_class":"path_traversal"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"icscert","cpe":[],"cvss":{"score":7.5,"severity":"high","source":"cna","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N","version":"3.1"},"cwes":[{"id":"CWE-25","name":"Path Traversal: '/../filedir'"}],"description":"Franklin Fueling System EVO 550 and EVO 5000 are vulnerable to a Path Traversal vulnerability that could allow an attacker to access sensitive files on the system.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"weaponised"},"has_fix":null,"headline":"Path Traversal vulnerability in Franklin Fueling System EVO 550/5000","id":"CVE-2024-2442","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"path_traversal","year":"2024"},"n_packages":0,"n_references":1,"next":{"headline":"Command injection in GitHub Enterprise Server","id":"CVE-2024-2443"},"packages":[],"prev":{"headline":"VikBooking \u003c 1.6.8 - Insecure Direct Object References","id":"CVE-2024-2441"},"products":["EVO 5000","EVO 550"],"published":"2024-03-19","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"yes","exploitation":"poc","technical_impact":"partial"},"state":"PUBLISHED","updated":"2024-08-28","vendors":["Franklin Fueling System"]},"summary":"An attacker can exploit a path traversal flaw in Franklin Fueling System EVO controllers to access sensitive files on the device.","url":"https://insights.sbomify.com/CVE-2024-2442/"}