{"answers":{"affected":"","exploited":"There is no known exploitation of CVE-2024-24972 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2024-24972 yet. Limit exposure of the affected software until one is available.","what":"CVE-2024-24972 is a medium-severity denial of service vulnerability in Gallagher Controller 6000 and Controller 7000, published on 11 Sep 2024. An attacker can exploit it over the internet without logging in, and only if a user opens a file or follows a link."},"fix_prompt":"Check this codebase for CVE-2024-24972 and fix it if it is affected.\n\nWhat it is: CVE-2024-24972 is a medium-severity denial of service vulnerability in Gallagher Controller 6000 and Controller 7000, published on 11 Sep 2024. An attacker can exploit it over the internet without logging in, and only if a user opens a file or follows a link.\nExploitation: There is no known exploitation of CVE-2024-24972 in the wild and no public exploit code.\n\nAffected product: Gallagher Controller 6000 and Controller 7000. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2024-24972/ (Markdown: https://insights.sbomify.com/CVE-2024-24972/index.md)","id":"CVE-2024-24972","markdown":"https://insights.sbomify.com/CVE-2024-24972/index.md","name":"CVE-2024-24972","record":{"aliases":["GHSA-4wp7-grq3-cjq2"],"analysis":{"component_type":"ics_ot","fix_type":"patch","impacts":["denial_of_service"],"network_reachable":"yes","non_default_config":true,"product_category":"Gallagher access controller","requires_auth":"none","summary":"An authenticated operator can cause a denial of service by rebooting the controller via the diagnostic web interface, which is disabled by default.","user_interaction":"required","vuln_class":"denial_of_service"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"Gallagher","cpe":[],"cvss":{"score":6.5,"severity":"medium","source":"cna","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H","version":"3.1"},"cwes":[{"id":"CWE-120","name":"Buffer Copy without Checking Size of Input"}],"description":"Buffer Copy without Checking Size of Input (CWE-120) in the Controller 6000 and Controller 7000 diagnostic web interface allows an authorised and authenticated operator to reboot the Controller, causing a Denial of Service. Gallagher recommend the diagnostic web page is not enabled (default is off) unless advised by Gallagher Technical support. This interface is intended only for diagnostic purposes.\n\nThis issue affects: Controller 6000 and Controller 7000 9.10 prior to vCR9.10.240816a (distributed in 9.10.1530 (MR2)), 9.00 prior to vCR9.00.240816a (distributed in 9.00.2168 (MR4)), 8.90 prior to vCR8.90.240816a (distributed in 8.90.2155 (MR5)), 8.80 prior to vCR8.80.240816b (distributed in 8.80.1938 (MR6)), all versions of 8.70 and prior.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Denial of service in Controller 6000 and Controller 7000","id":"CVE-2024-24972","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"denial_of_service","year":"2024"},"n_packages":0,"n_references":1,"next":{"headline":"Denial of service in Intel(R) Distribution for GDB software","id":"CVE-2024-24973"},"packages":[],"prev":{"headline":"Privilege escalation in HP Display Control","id":"CVE-2024-24970"},"products":["Controller 6000 and Controller 7000"],"published":"2024-09-11","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"partial"},"state":"PUBLISHED","updated":"2024-09-11","vendors":["Gallagher"]},"summary":"An authenticated operator can cause a denial of service by rebooting the controller via the diagnostic web interface, which is disabled by default.","url":"https://insights.sbomify.com/CVE-2024-24972/"}