{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2024-2559 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2024-2559 yet. Limit exposure of the affected software until one is available.","what":"CVE-2024-2559 is a medium-severity vulnerability in Tenda Ac18 Firmware, published on 17 Mar 2024. An attacker can exploit it over the internet without logging in, and only if a user opens a file or follows a link."},"fix_prompt":"Check this codebase for CVE-2024-2559 and fix it if it is affected.\n\nWhat it is: CVE-2024-2559 is a medium-severity vulnerability in Tenda Ac18 Firmware, published on 17 Mar 2024. An attacker can exploit it over the internet without logging in, and only if a user opens a file or follows a link.\nExploitation: There is no known exploitation of CVE-2024-2559 in the wild and no public exploit code.\n\nAffected product: Tenda Ac18 Firmware. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2024-2559/ (Markdown: https://insights.sbomify.com/CVE-2024-2559/index.md)","id":"CVE-2024-2559","markdown":"https://insights.sbomify.com/CVE-2024-2559/index.md","name":"CVE-2024-2559","record":{"aliases":["GHSA-wrg4-577q-37rc"],"analysis":{"component_type":"network_device","fix_type":"no_fix_stated","impacts":["security_bypass"],"network_reachable":"yes","non_default_config":false,"product_category":"Tenda AC18 router","requires_auth":"none","summary":"Attackers can force remote reboots of Tenda AC18 routers via CSRF, requiring user interaction to execute the malicious request.","user_interaction":"required","vuln_class":"csrf"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"VulDB","cpe":[{"product":"ac18_firmware","vendor":"tenda"}],"cvss":{"score":4.3,"severity":"medium","source":"cna","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:N","version":"3.1"},"cwes":[{"id":"CWE-352","name":"Cross-Site Request Forgery"}],"description":"A vulnerability classified as problematic has been found in Tenda AC18 15.03.05.05. Affected is the function fromSysToolReboot of the file /goform/SysToolReboot. The manipulation leads to cross-site request forgery. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-257058 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Tenda AC18 SysToolReboot fromSysToolReboot cross-site request forgery","id":"CVE-2024-2559","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":"tenda:ac18_firmware","products":["tenda:ac18_firmware"],"type":"csrf","year":"2024"},"n_packages":0,"n_references":3,"next":{"headline":"Tenda AC18 SysToolRestoreSet fromSysToolRestoreSet cross-site request forgery","id":"CVE-2024-2560"},"packages":[],"prev":{"headline":"Tenda AC18 execCommand formexeCommand stack-based overflow","id":"CVE-2024-2558"},"products":["AC18"],"published":"2024-03-17","related":[{"cvss_score":9.8,"headline":"Memory corruption in n/a","id":"CVE-2024-57575","kev_date_added":null,"published":"2025-01-16"},{"cvss_score":9.8,"headline":"Memory corruption in n/a","id":"CVE-2024-57579","kev_date_added":null,"published":"2025-01-16"},{"cvss_score":9.8,"headline":"Memory corruption in n/a","id":"CVE-2024-57580","kev_date_added":null,"published":"2025-01-16"},{"cvss_score":9.8,"headline":"Memory corruption in n/a","id":"CVE-2024-57581","kev_date_added":null,"published":"2025-01-16"},{"cvss_score":9.8,"headline":"Memory corruption in n/a","id":"CVE-2024-57582","kev_date_added":null,"published":"2025-01-16"},{"cvss_score":9.8,"headline":"Command injection in n/a","id":"CVE-2024-57583","kev_date_added":null,"published":"2025-01-16"},{"cvss_score":9.8,"headline":"Memory corruption in n/a","id":"CVE-2024-33835","kev_date_added":null,"published":"2024-05-01"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"partial"},"state":"PUBLISHED","updated":"2024-08-01","vendors":["Tenda"]},"summary":"Attackers can force remote reboots of Tenda AC18 routers via CSRF, requiring user interaction to execute the malicious request.","url":"https://insights.sbomify.com/CVE-2024-2559/"}