{"answers":{"affected":"It affects 1 product.","exploited":"It is not confirmed as exploited in the wild, but public exploit code for CVE-2024-2560 exists.","fix":"No fix has been published for CVE-2024-2560 yet. Limit exposure of the affected software until one is available.","what":"CVE-2024-2560 is a medium-severity vulnerability in Tenda Ac18 Firmware, published on 17 Mar 2024. An attacker can exploit it over the internet without logging in, and only if a user opens a file or follows a link."},"fix_prompt":"Check this codebase for CVE-2024-2560 and fix it if it is affected.\n\nWhat it is: CVE-2024-2560 is a medium-severity vulnerability in Tenda Ac18 Firmware, published on 17 Mar 2024. An attacker can exploit it over the internet without logging in, and only if a user opens a file or follows a link.\nExploitation: It is not confirmed as exploited in the wild, but public exploit code for CVE-2024-2560 exists.\n\nAffected product: Tenda Ac18 Firmware. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2024-2560/ (Markdown: https://insights.sbomify.com/CVE-2024-2560/index.md)","id":"CVE-2024-2560","markdown":"https://insights.sbomify.com/CVE-2024-2560/index.md","name":"CVE-2024-2560","record":{"aliases":["GHSA-ww9g-2qxc-wgxx"],"analysis":{"component_type":"network_device","fix_type":"no_fix_stated","impacts":["security_bypass"],"network_reachable":"yes","non_default_config":false,"product_category":"Tenda AC18 router","requires_auth":"none","summary":"Attackers can perform cross-site request forgery on Tenda AC18 routers to restore system settings, potentially bypassing security controls.","user_interaction":"required","vuln_class":"csrf"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"VulDB","cpe":[{"product":"ac18_firmware","vendor":"tenda"}],"cvss":{"score":4.3,"severity":"medium","source":"cna","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:N","version":"3.1"},"cwes":[{"id":"CWE-352","name":"Cross-Site Request Forgery"}],"description":"A vulnerability classified as problematic was found in Tenda AC18 15.03.05.05. Affected by this vulnerability is the function fromSysToolRestoreSet of the file /goform/SysToolRestoreSet. The manipulation leads to cross-site request forgery. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257059. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"weaponised"},"has_fix":null,"headline":"Tenda AC18 SysToolRestoreSet fromSysToolRestoreSet cross-site request forgery","id":"CVE-2024-2560","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":"tenda:ac18_firmware","products":["tenda:ac18_firmware"],"type":"csrf","year":"2024"},"n_packages":0,"n_references":3,"next":{"headline":"74CMS Company Logo Index.php#sendCompanyLogo unrestricted upload","id":"CVE-2024-2561"},"packages":[],"prev":{"headline":"Tenda AC18 SysToolReboot fromSysToolReboot cross-site request forgery","id":"CVE-2024-2559"},"products":["AC18"],"published":"2024-03-17","related":[{"cvss_score":9.8,"headline":"Memory corruption in n/a","id":"CVE-2024-57575","kev_date_added":null,"published":"2025-01-16"},{"cvss_score":9.8,"headline":"Memory corruption in n/a","id":"CVE-2024-57579","kev_date_added":null,"published":"2025-01-16"},{"cvss_score":9.8,"headline":"Memory corruption in n/a","id":"CVE-2024-57580","kev_date_added":null,"published":"2025-01-16"},{"cvss_score":9.8,"headline":"Memory corruption in n/a","id":"CVE-2024-57581","kev_date_added":null,"published":"2025-01-16"},{"cvss_score":9.8,"headline":"Memory corruption in n/a","id":"CVE-2024-57582","kev_date_added":null,"published":"2025-01-16"},{"cvss_score":9.8,"headline":"Command injection in n/a","id":"CVE-2024-57583","kev_date_added":null,"published":"2025-01-16"},{"cvss_score":9.8,"headline":"Memory corruption in n/a","id":"CVE-2024-33835","kev_date_added":null,"published":"2024-05-01"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"poc","technical_impact":"partial"},"state":"PUBLISHED","updated":"2024-08-05","vendors":["Tenda"]},"summary":"Attackers can perform cross-site request forgery on Tenda AC18 routers to restore system settings, potentially bypassing security controls.","url":"https://insights.sbomify.com/CVE-2024-2560/"}