{"answers":{"affected":"It affects 1 product.","exploited":"It is not confirmed as exploited in the wild, but public exploit code for CVE-2024-25852 exists.","fix":"No fix has been published for CVE-2024-25852 yet. Limit exposure of the affected software until one is available.","what":"CVE-2024-25852 is a high-severity command injection vulnerability in Linksys Re7000 Firmware, published on 11 Apr 2024. It can only be exploited from the same machine or local network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2024-25852 and fix it if it is affected.\n\nWhat it is: CVE-2024-25852 is a high-severity command injection vulnerability in Linksys Re7000 Firmware, published on 11 Apr 2024. It can only be exploited from the same machine or local network, with no action from the victim.\nExploitation: It is not confirmed as exploited in the wild, but public exploit code for CVE-2024-25852 exists.\n\nAffected product: Linksys Re7000 Firmware. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2024-25852/ (Markdown: https://insights.sbomify.com/CVE-2024-25852/index.md)","id":"CVE-2024-25852","markdown":"https://insights.sbomify.com/CVE-2024-25852/index.md","name":"CVE-2024-25852","record":{"aliases":["GHSA-p5q9-4vg3-6x89"],"analysis":{"component_type":"network_device","fix_type":"no_fix_stated","impacts":["code_execution","privilege_escalation"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"Linksys range extender","requires_auth":"none","summary":"Attackers can execute arbitrary commands via the AccessControlList parameter to gain administrator rights on Linksys RE7000 devices.","user_interaction":"not_required","vuln_class":"command_injection"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"mitre","cpe":[{"product":"re7000_firmware","vendor":"linksys"}],"cvss":{"score":8.8,"severity":"high","source":"cisa-adp","vector":"CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","version":"3.1"},"cwes":[{"id":"CWE-284","name":"Improper Access Control"}],"description":"Linksys RE7000 v2.0.9, v2.0.11, and v2.0.15 have a command execution vulnerability in the \"AccessControlList\" parameter of the access control function point. An attacker can use the vulnerability to obtain device administrator rights.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":1,"refs":[{"date":null,"kind":"nuclei","ref":"http/cves/2024/CVE-2024-25852.yaml","stars":null,"title":"Linksys RE7000 - Command Injection"}],"tier":"weaponised"},"has_fix":null,"headline":"Command injection in n/a","id":"CVE-2024-25852","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":"linksys:re7000_firmware","products":["linksys:re7000_firmware"],"type":"command_injection","year":"2024"},"n_packages":0,"n_references":2,"next":{"headline":"Cross-site scripting in n/a","id":"CVE-2024-25854"},"packages":[],"prev":{"headline":"Command injection in n/a","id":"CVE-2024-25851"},"products":["n/a"],"published":"2024-04-11","related":[{"cvss_score":8.4,"headline":"Memory corruption in n/a","id":"CVE-2025-60696","kev_date_added":null,"published":"2025-11-13"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"},{"class":"attribution","licence":"MIT","name":"Nuclei templates"}],"ssvc":{"automatable":"no","exploitation":"poc","technical_impact":"total"},"state":"PUBLISHED","updated":"2024-08-14","vendors":["n/a"]},"summary":"Attackers can execute arbitrary commands via the AccessControlList parameter to gain administrator rights on Linksys RE7000 devices.","url":"https://insights.sbomify.com/CVE-2024-25852/"}