{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2024-2708 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2024-2708 yet. Limit exposure of the affected software until one is available.","what":"CVE-2024-2708 is a high-severity memory corruption vulnerability in Tenda AC10U, published on 20 Mar 2024. Any signed-in user can exploit it over the network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2024-2708 and fix it if it is affected.\n\nWhat it is: CVE-2024-2708 is a high-severity memory corruption vulnerability in Tenda AC10U, published on 20 Mar 2024. Any signed-in user can exploit it over the network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2024-2708 in the wild and no public exploit code.\n\nAffected product: Tenda AC10U. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2024-2708/ (Markdown: https://insights.sbomify.com/CVE-2024-2708/index.md)","id":"CVE-2024-2708","markdown":"https://insights.sbomify.com/CVE-2024-2708/index.md","name":"CVE-2024-2708","record":{"aliases":["GHSA-x5f4-w9r3-6rpq"],"analysis":{"component_type":"network_device","fix_type":"no_fix_stated","impacts":["code_execution"],"network_reachable":"yes","non_default_config":false,"product_category":"Tenda AC10U router","requires_auth":"low_privilege","summary":"Remote attackers can trigger a stack-based buffer overflow in the execCommand function to execute arbitrary code on Tenda AC10U routers.","user_interaction":"not_required","vuln_class":"memory_corruption"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"VulDB","cpe":[{"product":"ac10u_firmware","vendor":"tenda"}],"cvss":{"score":8.8,"severity":"high","source":"cna","vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","version":"3.1"},"cwes":[{"id":"CWE-787","name":"Out-of-bounds Write"},{"id":"CWE-121","name":"Stack-based Buffer Overflow"}],"description":"A vulnerability was found in Tenda AC10U 15.03.06.49 and classified as critical. This issue affects the function formexeCommand of the file /goform/execCommand. The manipulation of the argument cmdinput leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257459. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Tenda AC10U execCommand formexeCommand stack-based overflow","id":"CVE-2024-2708","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"memory_corruption","year":"2024"},"n_packages":0,"n_references":3,"next":{"headline":"Tenda AC10U SetStaticRouteCfg fromSetRouteStatic stack-based overflow","id":"CVE-2024-2709"},"packages":[],"prev":{"headline":"Tenda AC10U WriteFacMac formWriteFacMac os command injection","id":"CVE-2024-2707"},"products":["AC10U"],"published":"2024-03-20","related":[{"cvss_score":8.8,"headline":"Tenda AC10U setcfm formSetCfm stack-based overflow","id":"CVE-2024-2763","kev_date_added":null,"published":"2024-03-21"},{"cvss_score":8.8,"headline":"Tenda AC10U SetPptpServerCfg formSetPPTPServer stack-based overflow","id":"CVE-2024-2764","kev_date_added":null,"published":"2024-03-21"},{"cvss_score":8.8,"headline":"Tenda AC10U SetOnlineDevName formSetDeviceName stack-based overflow","id":"CVE-2024-2703","kev_date_added":null,"published":"2024-03-20"},{"cvss_score":8.8,"headline":"Tenda AC10U SetFirewallCfg formSetFirewallCfg stack-based overflow","id":"CVE-2024-2704","kev_date_added":null,"published":"2024-03-20"},{"cvss_score":8.8,"headline":"Tenda AC10U SetNetControlList formSetQosBand stack-based overflow","id":"CVE-2024-2705","kev_date_added":null,"published":"2024-03-20"},{"cvss_score":8.8,"headline":"Tenda AC10U WifiWpsStart formWifiWpsStart stack-based overflow","id":"CVE-2024-2706","kev_date_added":null,"published":"2024-03-20"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"total"},"state":"PUBLISHED","updated":"2024-08-21","vendors":["Tenda"]},"summary":"Remote attackers can trigger a stack-based buffer overflow in the execCommand function to execute arbitrary code on Tenda AC10U routers.","url":"https://insights.sbomify.com/CVE-2024-2708/"}