{"answers":{"affected":"It affects 1 product.","exploited":"It is not confirmed as exploited in the wild, but public exploit code for CVE-2024-2711 exists.","fix":"No fix has been published for CVE-2024-2711 yet. Limit exposure of the affected software until one is available.","what":"CVE-2024-2711 is a high-severity memory corruption vulnerability in Tenda AC10U, published on 20 Mar 2024. Any signed-in user can exploit it over the network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2024-2711 and fix it if it is affected.\n\nWhat it is: CVE-2024-2711 is a high-severity memory corruption vulnerability in Tenda AC10U, published on 20 Mar 2024. Any signed-in user can exploit it over the network, with no action from the victim.\nExploitation: It is not confirmed as exploited in the wild, but public exploit code for CVE-2024-2711 exists.\n\nAffected product: Tenda AC10U. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2024-2711/ (Markdown: https://insights.sbomify.com/CVE-2024-2711/index.md)","id":"CVE-2024-2711","markdown":"https://insights.sbomify.com/CVE-2024-2711/index.md","name":"CVE-2024-2711","record":{"aliases":["GHSA-h9rc-rj87-48r4"],"analysis":{"component_type":"network_device","fix_type":"no_fix_stated","impacts":["code_execution"],"network_reachable":"yes","non_default_config":false,"product_category":"Tenda AC10U router","requires_auth":"low_privilege","summary":"Remote attackers can trigger a stack-based buffer overflow in the Tenda AC10U router's MAC filter function, potentially leading to arbitrary code execution.","user_interaction":"not_required","vuln_class":"memory_corruption"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"VulDB","cpe":[{"product":"ac10u_firmware","vendor":"tenda"}],"cvss":{"score":8.8,"severity":"high","source":"cna","vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","version":"3.1"},"cwes":[{"id":"CWE-787","name":"Out-of-bounds Write"},{"id":"CWE-121","name":"Stack-based Buffer Overflow"}],"description":"A vulnerability was found in Tenda AC10U 15.03.06.48. It has been rated as critical. Affected by this issue is the function addWifiMacFilter of the file /goform/addWifiMacFilter. The manipulation of the argument deviceMac leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-257462 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"weaponised"},"has_fix":null,"headline":"Tenda AC10U addWifiMacFilter stack-based overflow","id":"CVE-2024-2711","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"memory_corruption","year":"2024"},"n_packages":0,"n_references":3,"next":{"headline":"Campcodes Complete Online DJ Booking System user-search.php sql injection","id":"CVE-2024-2712"},"packages":[],"prev":{"headline":"Tenda AC10U openSchedWifi setSchedWifi stack-based overflow","id":"CVE-2024-2710"},"products":["AC10U"],"published":"2024-03-20","related":[{"cvss_score":8.8,"headline":"Tenda AC10U setcfm formSetCfm stack-based overflow","id":"CVE-2024-2763","kev_date_added":null,"published":"2024-03-21"},{"cvss_score":8.8,"headline":"Tenda AC10U SetPptpServerCfg formSetPPTPServer stack-based overflow","id":"CVE-2024-2764","kev_date_added":null,"published":"2024-03-21"},{"cvss_score":8.8,"headline":"Tenda AC10U SetOnlineDevName formSetDeviceName stack-based overflow","id":"CVE-2024-2703","kev_date_added":null,"published":"2024-03-20"},{"cvss_score":8.8,"headline":"Tenda AC10U SetFirewallCfg formSetFirewallCfg stack-based overflow","id":"CVE-2024-2704","kev_date_added":null,"published":"2024-03-20"},{"cvss_score":8.8,"headline":"Tenda AC10U SetNetControlList formSetQosBand stack-based overflow","id":"CVE-2024-2705","kev_date_added":null,"published":"2024-03-20"},{"cvss_score":8.8,"headline":"Tenda AC10U WifiWpsStart formWifiWpsStart stack-based overflow","id":"CVE-2024-2706","kev_date_added":null,"published":"2024-03-20"},{"cvss_score":8.8,"headline":"Tenda AC10U execCommand formexeCommand stack-based overflow","id":"CVE-2024-2708","kev_date_added":null,"published":"2024-03-20"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"poc","technical_impact":"partial"},"state":"PUBLISHED","updated":"2024-08-21","vendors":["Tenda"]},"summary":"Remote attackers can trigger a stack-based buffer overflow in the Tenda AC10U router's MAC filter function, potentially leading to arbitrary code execution.","url":"https://insights.sbomify.com/CVE-2024-2711/"}