{"answers":{"affected":"It affects 1 product.","exploited":"It is not confirmed as exploited in the wild, but public exploit code for CVE-2024-2898 exists.","fix":"No fix has been published for CVE-2024-2898 yet. Limit exposure of the affected software until one is available.","what":"CVE-2024-2898 is a high-severity memory corruption vulnerability in Tenda Ac7 Firmware, published on 26 Mar 2024. Any signed-in user can exploit it over the network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2024-2898 and fix it if it is affected.\n\nWhat it is: CVE-2024-2898 is a high-severity memory corruption vulnerability in Tenda Ac7 Firmware, published on 26 Mar 2024. Any signed-in user can exploit it over the network, with no action from the victim.\nExploitation: It is not confirmed as exploited in the wild, but public exploit code for CVE-2024-2898 exists.\n\nAffected product: Tenda Ac7 Firmware. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2024-2898/ (Markdown: https://insights.sbomify.com/CVE-2024-2898/index.md)","id":"CVE-2024-2898","markdown":"https://insights.sbomify.com/CVE-2024-2898/index.md","name":"CVE-2024-2898","record":{"aliases":["GHSA-cpvw-pm4w-xwgm"],"analysis":{"component_type":"network_device","fix_type":"no_fix_stated","impacts":["code_execution","denial_of_service"],"network_reachable":"yes","non_default_config":false,"product_category":"Tenda AC7 router","requires_auth":"low_privilege","summary":"Remote attackers can trigger a stack-based buffer overflow in the Tenda AC7 router's static route configuration, potentially leading to code execution or denial of service.","user_interaction":"not_required","vuln_class":"memory_corruption"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"VulDB","cpe":[{"product":"ac7_firmware","vendor":"tenda"}],"cvss":{"score":8.8,"severity":"high","source":"cna","vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","version":"3.1"},"cwes":[{"id":"CWE-787","name":"Out-of-bounds Write"},{"id":"CWE-121","name":"Stack-based Buffer Overflow"}],"description":"A vulnerability classified as critical was found in Tenda AC7 15.03.06.44. Affected by this vulnerability is the function fromSetRouteStatic of the file /goform/SetStaticRouteCfg. The manipulation of the argument list leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257941 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"weaponised"},"has_fix":null,"headline":"Tenda AC7 SetStaticRouteCfg fromSetRouteStatic stack-based overflow","id":"CVE-2024-2898","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":"tenda:ac7_firmware","products":["tenda:ac7_firmware"],"type":"memory_corruption","year":"2024"},"n_packages":0,"n_references":4,"next":{"headline":"Tenda AC7 WifiExtraSet fromSetWirelessRepeat stack-based overflow","id":"CVE-2024-2899"},"packages":[],"prev":{"headline":"Tenda AC7 WriteFacMac formWriteFacMac os command injection","id":"CVE-2024-2897"},"products":["AC7"],"published":"2024-03-26","related":[{"cvss_score":9.8,"headline":"Memory corruption in n/a","id":"CVE-2026-51843","kev_date_added":null,"published":"2026-06-19"},{"cvss_score":9.8,"headline":"Memory corruption in n/a","id":"CVE-2026-51844","kev_date_added":null,"published":"2026-06-19"},{"cvss_score":9.8,"headline":"Memory corruption in n/a","id":"CVE-2026-51845","kev_date_added":null,"published":"2026-06-19"},{"cvss_score":9.8,"headline":"Memory corruption in n/a","id":"CVE-2026-51846","kev_date_added":null,"published":"2026-06-19"},{"cvss_score":9.8,"headline":"Memory corruption in n/a","id":"CVE-2025-29135","kev_date_added":null,"published":"2025-03-24"},{"cvss_score":9.8,"headline":"Memory corruption in n/a","id":"CVE-2025-29137","kev_date_added":null,"published":"2025-03-19"},{"cvss_score":9.8,"headline":"Memory corruption in n/a","id":"CVE-2024-32301","kev_date_added":null,"published":"2024-04-17"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"poc","technical_impact":"total"},"state":"PUBLISHED","updated":"2024-08-01","vendors":["Tenda"]},"summary":"Remote attackers can trigger a stack-based buffer overflow in the Tenda AC7 router's static route configuration, potentially leading to code execution or denial of service.","url":"https://insights.sbomify.com/CVE-2024-2898/"}