{"answers":{"affected":"","exploited":"There is no known exploitation of CVE-2024-29207 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2024-29207 yet. Limit exposure of the affected software until one is available.","what":"CVE-2024-29207 is a high-severity vulnerability in Ubiquiti Inc UniFi Connect Application, published on 7 May 2024. It can only be exploited from the same machine or local network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2024-29207 and fix it if it is affected.\n\nWhat it is: CVE-2024-29207 is a high-severity vulnerability in Ubiquiti Inc UniFi Connect Application, published on 7 May 2024. It can only be exploited from the same machine or local network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2024-29207 in the wild and no public exploit code.\n\nAffected product: Ubiquiti Inc UniFi Connect Application. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2024-29207/ (Markdown: https://insights.sbomify.com/CVE-2024-29207/index.md)","id":"CVE-2024-29207","markdown":"https://insights.sbomify.com/CVE-2024-29207/index.md","name":"CVE-2024-29207","record":{"aliases":["GHSA-x7p4-m95h-xjv4"],"analysis":{"component_type":"iot_embedded","fix_type":"upgrade","impacts":["code_execution","privilege_escalation"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"UniFi Connect devices","requires_auth":"none","summary":"Improper certificate validation allows adjacent network attackers to take control of UniFi Connect devices.","user_interaction":"not_required","vuln_class":"security_feature_bypass"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"hackerone","cpe":[],"cvss":{"score":7.5,"severity":"high","source":"cna","vector":"CVSS:3.0/AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H","version":"3.0"},"cwes":[{"id":"CWE-284","name":"Improper Access Control"}],"description":"An Improper Certificate Validation could allow a malicious actor with access to an adjacent network to take control of the system. \n\n \n\nAffected Products:\n\nUniFi Connect Application (Version 3.7.9 and earlier) \n\nUniFi Connect EV Station (Version 1.1.18 and earlier) \n\nUniFi Connect EV Station Pro (Version 1.1.18 and earlier)\n\nUniFi Connect Display (Version 1.9.324 and earlier)\n\nUniFi Connect Display Cast (Version 1.6.225 and earlier)\n\n \n\nMitigation:\n\nUpdate UniFi Connect Application to Version 3.10.7 or later.\n\nUpdate UniFi Connect EV Station to Version 1.2.15 or later.\n\nUpdate UniFi Connect EV Station Pro to Version 1.2.15 or later.\n\nUpdate UniFi Connect Display to Version 1.11.348 or later.\n\nUpdate UniFi Connect Display Cast to Version 1.8.255 or later.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Security feature bypass in UniFi Connect Application","id":"CVE-2024-29207","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"security_feature_bypass","year":"2024"},"n_packages":0,"n_references":1,"next":{"headline":"Auth bypass in Update UniFi Connect Display","id":"CVE-2024-29208"},"packages":[],"prev":{"headline":"Missing authorization in UniFi Access G2 Reader Pro","id":"CVE-2024-29206"},"products":["UniFi Connect Application","UniFi Connect Display","UniFi Connect Display Cast","UniFi Connect EV Station","UniFi Connect EV Station Pro "],"published":"2024-05-07","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"total"},"state":"PUBLISHED","updated":"2024-08-02","vendors":["Ubiquiti Inc"]},"summary":"Improper certificate validation allows adjacent network attackers to take control of UniFi Connect devices.","url":"https://insights.sbomify.com/CVE-2024-29207/"}