{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2024-2980 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2024-2980 yet. Limit exposure of the affected software until one is available.","what":"CVE-2024-2980 is a high-severity memory corruption vulnerability in Tenda Fh1202 Firmware, published on 27 Mar 2024. Any signed-in user can exploit it over the network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2024-2980 and fix it if it is affected.\n\nWhat it is: CVE-2024-2980 is a high-severity memory corruption vulnerability in Tenda Fh1202 Firmware, published on 27 Mar 2024. Any signed-in user can exploit it over the network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2024-2980 in the wild and no public exploit code.\n\nAffected product: Tenda Fh1202 Firmware. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2024-2980/ (Markdown: https://insights.sbomify.com/CVE-2024-2980/index.md)","id":"CVE-2024-2980","markdown":"https://insights.sbomify.com/CVE-2024-2980/index.md","name":"CVE-2024-2980","record":{"aliases":["GHSA-9p7q-wmmc-3rgf"],"analysis":{"component_type":"network_device","fix_type":"no_fix_stated","impacts":["code_execution"],"network_reachable":"yes","non_default_config":false,"product_category":"Tenda FH1202 router","requires_auth":"low_privilege","summary":"Remote attackers can trigger a stack-based buffer overflow in the Tenda FH1202 router's execCommand function to execute arbitrary code.","user_interaction":"not_required","vuln_class":"memory_corruption"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"VulDB","cpe":[{"product":"fh1202_firmware","vendor":"tenda"}],"cvss":{"score":8.8,"severity":"high","source":"cna","vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","version":"3.1"},"cwes":[{"id":"CWE-787","name":"Out-of-bounds Write"},{"id":"CWE-121","name":"Stack-based Buffer Overflow"}],"description":"A vulnerability, which was classified as critical, has been found in Tenda FH1202 1.2.0.14(408). This issue affects the function formexeCommand of the file /goform/execCommand. The manipulation of the argument cmdinput leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-258149 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Tenda FH1202 execCommand formexeCommand stack-based overflow","id":"CVE-2024-2980","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":"tenda:fh1202_firmware","products":["tenda:fh1202_firmware"],"type":"memory_corruption","year":"2024"},"n_packages":0,"n_references":4,"next":{"headline":"Tenda FH1202 fast_setting_wifi_set form_fast_setting_wifi_set stack-based overflow","id":"CVE-2024-2981"},"packages":[],"prev":{"headline":"Tenda F1203 openSchedWifi setSchedWifi stack-based overflow","id":"CVE-2024-2979"},"products":["FH1202"],"published":"2024-03-27","related":[{"cvss_score":9.8,"headline":"Memory corruption in n/a","id":"CVE-2024-30584","kev_date_added":null,"published":"2024-03-28"},{"cvss_score":9.8,"headline":"Memory corruption in n/a","id":"CVE-2024-30587","kev_date_added":null,"published":"2024-03-28"},{"cvss_score":9.8,"headline":"Memory corruption in n/a","id":"CVE-2024-30589","kev_date_added":null,"published":"2024-03-28"},{"cvss_score":9.8,"headline":"Memory corruption in n/a","id":"CVE-2024-30593","kev_date_added":null,"published":"2024-03-28"},{"cvss_score":9.8,"headline":"Memory corruption in n/a","id":"CVE-2024-30595","kev_date_added":null,"published":"2024-03-28"},{"cvss_score":9.8,"headline":"Memory corruption in n/a","id":"CVE-2024-30596","kev_date_added":null,"published":"2024-03-28"},{"cvss_score":8.8,"headline":"Memory corruption in n/a","id":"CVE-2024-30591","kev_date_added":null,"published":"2024-03-28"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"total"},"state":"PUBLISHED","updated":"2024-08-01","vendors":["Tenda"]},"summary":"Remote attackers can trigger a stack-based buffer overflow in the Tenda FH1202 router's execCommand function to execute arbitrary code.","url":"https://insights.sbomify.com/CVE-2024-2980/"}