{"answers":{"affected":"","exploited":"There is no known exploitation of CVE-2024-30191 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2024-30191 yet. Limit exposure of the affected software until one is available.","what":"CVE-2024-30191 is a high-severity authentication bypass vulnerability in Siemens SCALANCE W1748-1 M12, published on 9 Apr 2024. It can only be exploited from the same machine or local network, and only if a user opens a file or follows a link."},"fix_prompt":"Check this codebase for CVE-2024-30191 and fix it if it is affected.\n\nWhat it is: CVE-2024-30191 is a high-severity authentication bypass vulnerability in Siemens SCALANCE W1748-1 M12, published on 9 Apr 2024. It can only be exploited from the same machine or local network, and only if a user opens a file or follows a link.\nExploitation: There is no known exploitation of CVE-2024-30191 in the wild and no public exploit code.\n\nAffected product: Siemens SCALANCE W1748-1 M12. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2024-30191/ (Markdown: https://insights.sbomify.com/CVE-2024-30191/index.md)","id":"CVE-2024-30191","markdown":"https://insights.sbomify.com/CVE-2024-30191/index.md","name":"CVE-2024-30191","record":{"aliases":["GHSA-r4cp-3jcm-fv88"],"analysis":{"component_type":"network_device","fix_type":"patch","impacts":["security_bypass"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"Siemens SCALANCE wireless","requires_auth":"low_privilege","summary":"Attackers can bypass authentication mechanisms on Siemens SCALANCE wireless devices due to spoofing vulnerabilities.","user_interaction":"required","vuln_class":"auth_bypass"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"siemens","cpe":[],"cvss":{"score":8.4,"severity":"high","source":"cna","vector":"CVSS:3.1/AV:A/AC:L/PR:L/UI:R/S:C/C:H/I:H/A:H","version":"3.1"},"cwes":[{"id":"CWE-290","name":"Authentication Bypass by Spoofing"}],"description":"A vulnerability has been identified in SCALANCE W1748-1 M12 (6GK5748-1GY01-0AA0), SCALANCE W1748-1 M12 (6GK5748-1GY01-0TA0), SCALANCE W1788-1 M12 (6GK5788-1GY01-0AA0), SCALANCE W1788-2 EEC M12 (6GK5788-2GY01-0TA0), SCALANCE W1788-2 M12 (6GK5788-2GY01-0AA0), SCALANCE W1788-2IA M12 (6GK5788-2HY01-0AA0), SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AA0), SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AB0), SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AA0), SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AB0), SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AC0), SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA0), SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA6), SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AB0), SCALANCE W734-1 RJ45 (USA) (6GK5734-1FX00-0AB6), SCALANCE W738-1 M12 (6GK5738-1GY00-0AA0), SCALANCE W738-1 M12 (6GK5738-1GY00-0AB0), SCALANCE W748-1 M12 (6GK5748-1GD00-0AA0), SCALANCE W748-1 M12 (6GK5748-1GD00-0AB0), SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AA0), SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AB0), SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AA0), SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AB0), SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TA0), SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TB0), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA0), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA6), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AB0), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AC0), SCALANCE W774-1 RJ45 (USA) (6GK5774-1FX00-0AB6), SCALANCE W778-1 M12 (6GK5778-1GY00-0AA0), SCALANCE W778-1 M12 (6GK5778-1GY00-0AB0), SCALANCE W778-1 M12 EEC (6GK5778-1GY00-0TA0), SCALANCE W778-1 M12 EEC (USA) (6GK5778-1GY00-0TB0), SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AA0), SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AB0), SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AA0), SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AB0), SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AC0), SCALANCE W786-2 SFP (6GK5786-2FE00-0AA0), SCALANCE W786-2 SFP (6GK5786-2FE00-0AB0), SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AA0), SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AB0), SCALANCE W788-1 M12 (6GK5788-1GD00-0AA0), SCALANCE W788-1 M12 (6GK5788-1GD00-0AB0), SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AA0), SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AB0), SCALANCE W788-2 M12 (6GK5788-2GD00-0AA0), SCALANCE W788-2 M12 (6GK5788-2GD00-0AB0), SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TA0), SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TB0), SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TC0), SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AA0), SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AB0), SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AC0), SCALANCE WAM763-1 (6GK5763-1AL00-7DA0), SCALANCE WAM766-1 (EU) (6GK5766-1GE00-7DA0), SCALANCE WAM766-1 (US) (6GK5766-1GE00-7DB0), SCALANCE WAM766-1 EEC (EU) (6GK5766-1GE00-7TA0), SCALANCE WAM766-1 EEC (US) (6GK5766-1GE00-7TB0), SCALANCE WUM763-1 (6GK5763-1AL00-3AA0), SCALANCE WUM763-1 (6GK5763-1AL00-3DA0), SCALANCE WUM766-1 (EU) (6GK5766-1GE00-3DA0), SCALANCE WUM766-1 (US) (6GK5766-1GE00-3DB0). This CVE refers to Scenario 3 \"Override client’s security context\" of CVE-2022-47522.\r\n\r\nAffected devices can be tricked into associating a newly negotiated, attacker-controlled, security context with frames belonging to a victim. This could allow a physically proximate attacker to decrypt frames meant for the victim.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Auth bypass in SCALANCE W1748-1 M12","id":"CVE-2024-30191","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"auth_bypass","year":"2024"},"n_packages":0,"n_references":1,"next":{"headline":"WordPress Pinterest Plugin \u003c= 1.8.2 - Cross Site Scripting (XSS)","id":"CVE-2024-30192"},"packages":[],"prev":{"headline":"Auth bypass in SCALANCE W1748-1 M12","id":"CVE-2024-30190"},"products":["SCALANCE W1748-1 M12","SCALANCE W1788-1 M12","SCALANCE W1788-2 EEC M12","SCALANCE W1788-2 M12","SCALANCE W1788-2IA M12","SCALANCE W721-1 RJ45","SCALANCE W722-1 RJ45","SCALANCE W734-1 RJ45","SCALANCE W734-1 RJ45 (USA)","SCALANCE W738-1 M12","SCALANCE W748-1 M12","SCALANCE W748-1 RJ45","SCALANCE W761-1 RJ45","SCALANCE W774-1 M12 EEC","SCALANCE W774-1 RJ45","SCALANCE W774-1 RJ45 (USA)","SCALANCE W778-1 M12","SCALANCE W778-1 M12 EEC","SCALANCE W778-1 M12 EEC (USA)","SCALANCE W786-1 RJ45","SCALANCE W786-2 RJ45","SCALANCE W786-2 SFP","SCALANCE W786-2IA RJ45","SCALANCE W788-1 M12","SCALANCE W788-1 RJ45","SCALANCE W788-2 M12","SCALANCE W788-2 M12 EEC","SCALANCE W788-2 RJ45","SCALANCE WAM763-1","SCALANCE WAM766-1 (EU)","SCALANCE WAM766-1 (US)","SCALANCE WAM766-1 EEC (EU)","SCALANCE WAM766-1 EEC (US)","SCALANCE WUM763-1","SCALANCE WUM766-1 (EU)","SCALANCE WUM766-1 (US)"],"published":"2024-04-09","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"total"},"state":"PUBLISHED","updated":"2024-08-27","vendors":["Siemens"]},"summary":"Attackers can bypass authentication mechanisms on Siemens SCALANCE wireless devices due to spoofing vulnerabilities.","url":"https://insights.sbomify.com/CVE-2024-30191/"}