{"answers":{"affected":"","exploited":"There is no known exploitation of CVE-2024-30207 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2024-30207 yet. Limit exposure of the affected software until one is available.","what":"CVE-2024-30207 is a critical vulnerability in Siemens SIMATIC RTLS Locating Manager, published on 14 May 2024. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2024-30207 and fix it if it is affected.\n\nWhat it is: CVE-2024-30207 is a critical vulnerability in Siemens SIMATIC RTLS Locating Manager, published on 14 May 2024. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2024-30207 in the wild and no public exploit code.\n\nAffected product: Siemens SIMATIC RTLS Locating Manager. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2024-30207/ (Markdown: https://insights.sbomify.com/CVE-2024-30207/index.md)","id":"CVE-2024-30207","markdown":"https://insights.sbomify.com/CVE-2024-30207/index.md","name":"CVE-2024-30207","record":{"aliases":["GHSA-gfmq-99p2-3jwp"],"analysis":{"component_type":"ics_ot","fix_type":"upgrade","impacts":["data_read","data_modify","denial_of_service"],"network_reachable":"yes","non_default_config":false,"product_category":"RTLS Locating Manager","requires_auth":"none","summary":"An attacker with network access and knowledge of a hard-coded key can compromise the confidentiality, integrity, and availability of SIMATIC RTLS communications.","user_interaction":"not_required","vuln_class":"hardcoded_credentials"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"siemens","cpe":[],"cvss":{"score":10,"severity":"critical","source":"cna","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H","version":"4.0"},"cwes":[{"id":"CWE-321","name":"Use of Hard-coded Cryptographic Key"}],"description":"A vulnerability has been identified in SIMATIC RTLS Locating Manager (6GT2780-0DA00) (All versions \u003c V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA10) (All versions \u003c V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA20) (All versions \u003c V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA30) (All versions \u003c V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA10) (All versions \u003c V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA20) (All versions \u003c V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA30) (All versions \u003c V3.0.1.1). The affected systems use symmetric cryptography with a hard-coded key to protect the communication between client and server. This could allow an unauthenticated remote attacker to compromise confidentiality and integrity of the communication and, subsequently, availability of the system.\r\nA successful exploit requires the attacker to gain knowledge of the hard-coded key and to be able to intercept the communication between client and server on the network.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Hardcoded credentials in SIMATIC RTLS Locating Manager","id":"CVE-2024-30207","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"hardcoded_credentials","year":"2024"},"n_packages":0,"n_references":1,"next":{"headline":"Information disclosure in SIMATIC RTLS Locating Manager","id":"CVE-2024-30208"},"packages":[],"prev":{"headline":"Code injection in SIMATIC RTLS Locating Manager","id":"CVE-2024-30206"},"products":["SIMATIC RTLS Locating Manager"],"published":"2024-05-14","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"yes","exploitation":"none","technical_impact":"total"},"state":"PUBLISHED","updated":"2024-08-02","vendors":["Siemens"]},"summary":"An attacker with network access and knowledge of a hard-coded key can compromise the confidentiality, integrity, and availability of SIMATIC RTLS communications.","url":"https://insights.sbomify.com/CVE-2024-30207/"}