{"answers":{"affected":"","exploited":"There is no known exploitation of CVE-2024-30321 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2024-30321 yet. Limit exposure of the affected software until one is available.","what":"CVE-2024-30321 is a high-severity vulnerability in Siemens SIMATIC PCS 7 V9.1, published on 9 Jul 2024. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2024-30321 and fix it if it is affected.\n\nWhat it is: CVE-2024-30321 is a high-severity vulnerability in Siemens SIMATIC PCS 7 V9.1, published on 9 Jul 2024. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2024-30321 in the wild and no public exploit code.\n\nAffected product: Siemens SIMATIC PCS 7 V9.1. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2024-30321/ (Markdown: https://insights.sbomify.com/CVE-2024-30321/index.md)","id":"CVE-2024-30321","markdown":"https://insights.sbomify.com/CVE-2024-30321/index.md","name":"CVE-2024-30321","record":{"aliases":["GHSA-x843-fv8x-w437"],"analysis":{"component_type":"ics_ot","fix_type":"upgrade","impacts":["data_read"],"network_reachable":"yes","non_default_config":false,"product_category":"Siemens SCADA software","requires_auth":"none","summary":"Unauthenticated remote attackers can retrieve privileged information, including user credentials, from affected Siemens SCADA and HMI web applications.","user_interaction":"not_required","vuln_class":"information_disclosure"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"siemens","cpe":[],"cvss":{"score":8.2,"severity":"high","source":"cna","vector":"CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N","version":"4.0"},"cwes":[{"id":"CWE-359","name":"Exposure of Private Personal Information to an Unauthorized Actor"}],"description":"A vulnerability has been identified in SIMATIC PCS 7 V9.1 (All versions \u003c V9.1 SP2 UC05), SIMATIC WinCC Runtime Professional V18 (All versions \u003c V18 Update 5), SIMATIC WinCC Runtime Professional V19 (All versions \u003c V19 Update 2), SIMATIC WinCC V7.4 (All versions \u003c V7.4 SP1 Update 23), SIMATIC WinCC V7.5 (All versions \u003c V7.5 SP2 Update 17), SIMATIC WinCC V8.0 (All versions \u003c V8.0 Update 5). The affected products do not properly handle certain requests to their web application, which may lead to the leak of privileged information.\r\nThis could allow an unauthenticated remote attacker to retrieve information such as users and passwords.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Information disclosure in SIMATIC PCS 7 V9.1","id":"CVE-2024-30321","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"information_disclosure","year":"2024"},"n_packages":0,"n_references":1,"next":{"headline":"Foxit PDF Reader AcroForm Use-After-Free Remote Code Execution Vulnerability","id":"CVE-2024-30322"},"packages":[],"prev":{"headline":"Command injection in Dreamweaver Desktop","id":"CVE-2024-30314"},"products":["SIMATIC PCS 7 V9.1","SIMATIC WinCC Runtime Professional V18","SIMATIC WinCC Runtime Professional V19","SIMATIC WinCC V7.4","SIMATIC WinCC V7.5","SIMATIC WinCC V8.0"],"published":"2024-07-09","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"total"},"state":"PUBLISHED","updated":"2025-08-27","vendors":["Siemens"]},"summary":"Unauthenticated remote attackers can retrieve privileged information, including user credentials, from affected Siemens SCADA and HMI web applications.","url":"https://insights.sbomify.com/CVE-2024-30321/"}