{"answers":{"affected":"It affects 1 product.","exploited":"It is not confirmed as exploited in the wild, but public exploit code for CVE-2024-30645 exists.","fix":"No fix has been published for CVE-2024-30645 yet. Limit exposure of the affected software until one is available.","what":"CVE-2024-30645 is a high-severity command injection vulnerability in Tenda Ac15 Firmware, published on 29 Mar 2024. It can only be exploited from the same machine or local network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2024-30645 and fix it if it is affected.\n\nWhat it is: CVE-2024-30645 is a high-severity command injection vulnerability in Tenda Ac15 Firmware, published on 29 Mar 2024. It can only be exploited from the same machine or local network, with no action from the victim.\nExploitation: It is not confirmed as exploited in the wild, but public exploit code for CVE-2024-30645 exists.\n\nAffected product: Tenda Ac15 Firmware. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2024-30645/ (Markdown: https://insights.sbomify.com/CVE-2024-30645/index.md)","id":"CVE-2024-30645","markdown":"https://insights.sbomify.com/CVE-2024-30645/index.md","name":"CVE-2024-30645","record":{"aliases":["GHSA-2v5w-v683-c839"],"analysis":{"component_type":"network_device","fix_type":"no_fix_stated","impacts":["code_execution"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"Tenda AC15 router","requires_auth":"low_privilege","summary":"Attackers can execute arbitrary commands on Tenda AC15 routers via the deviceName parameter, potentially compromising the device.","user_interaction":"not_required","vuln_class":"command_injection"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"mitre","cpe":[{"product":"ac15_firmware","vendor":"tenda"}],"cvss":{"score":8,"severity":"high","source":"cisa-adp","vector":"CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","version":"3.1"},"cwes":[{"id":"CWE-78","name":"Improper Neutralization of Special Elements used in an OS Command"}],"description":"Tenda AC15V1.0 V15.03.20_multi has a command injection vulnerability via the deviceName parameter.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"weaponised"},"has_fix":null,"headline":"Command injection in n/a","id":"CVE-2024-30645","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":"tenda:ac15_firmware","products":["tenda:ac15_firmware"],"type":"command_injection","year":"2024"},"n_packages":0,"n_references":1,"next":{"headline":"Denial of service in n/a","id":"CVE-2024-30656"},"packages":[],"prev":{"headline":"Memory corruption in n/a","id":"CVE-2024-30639"},"products":["n/a"],"published":"2024-03-29","related":[{"cvss_score":9.8,"headline":"Tenda AC1900 Router AC15 Model Remote Code Execution","id":"CVE-2020-10987","kev_date_added":"2021-11-03","published":"2020-07-13"},{"cvss_score":9.8,"headline":"Memory corruption in n/a","id":"CVE-2026-24103","kev_date_added":null,"published":"2026-03-03"},{"cvss_score":9.8,"headline":"Command injection in n/a","id":"CVE-2026-24101","kev_date_added":null,"published":"2026-03-02"},{"cvss_score":9.8,"headline":"Command injection in n/a","id":"CVE-2026-24105","kev_date_added":null,"published":"2026-03-02"},{"cvss_score":9.8,"headline":"Information disclosure in n/a","id":"CVE-2025-63666","kev_date_added":null,"published":"2025-11-12"},{"cvss_score":9.8,"headline":"Memory corruption in n/a","id":"CVE-2025-29462","kev_date_added":null,"published":"2025-04-03"},{"cvss_score":9.8,"headline":"Command injection in n/a","id":"CVE-2025-25632","kev_date_added":null,"published":"2025-03-05"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"poc","technical_impact":"total"},"state":"PUBLISHED","updated":"2024-08-02","vendors":["n/a"]},"summary":"Attackers can execute arbitrary commands on Tenda AC15 routers via the deviceName parameter, potentially compromising the device.","url":"https://insights.sbomify.com/CVE-2024-30645/"}