{"answers":{"affected":"","exploited":"There is no known exploitation of CVE-2024-32011 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2024-32011 yet. Limit exposure of the affected software until one is available.","what":"CVE-2024-32011 is a high-severity command injection vulnerability in Siemens Spectrum Power 4, published on 11 Nov 2025. Any signed-in user can exploit it over the network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2024-32011 and fix it if it is affected.\n\nWhat it is: CVE-2024-32011 is a high-severity command injection vulnerability in Siemens Spectrum Power 4, published on 11 Nov 2025. Any signed-in user can exploit it over the network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2024-32011 in the wild and no public exploit code.\n\nAffected product: Siemens Spectrum Power 4. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2024-32011/ (Markdown: https://insights.sbomify.com/CVE-2024-32011/index.md)","id":"CVE-2024-32011","markdown":"https://insights.sbomify.com/CVE-2024-32011/index.md","name":"CVE-2024-32011","record":{"aliases":["GHSA-wrgq-x2fx-9ww7"],"analysis":{"component_type":"ics_ot","fix_type":"upgrade","impacts":["code_execution","privilege_escalation"],"network_reachable":"yes","non_default_config":false,"product_category":"Siemens Spectrum Power 4","requires_auth":"low_privilege","summary":"Attackers can execute arbitrary commands as an administrative user via the network-accessible user interface in Siemens Spectrum Power 4.","user_interaction":"not_required","vuln_class":"command_injection"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"siemens","cpe":[],"cvss":{"score":8.7,"severity":"high","source":"cna","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","version":"4.0"},"cwes":[{"id":"CWE-829","name":"Inclusion of Functionality from Untrusted Control Sphere"}],"description":"A vulnerability has been identified in Spectrum Power 4 (All versions \u003c V4.70 SP12 Update 2). The affected application is vulnerable to run arbitrary commands via the user interface. This user interface can be used via the network and allows the execution of commands as administrative application user.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Command injection in Spectrum Power 4","id":"CVE-2024-32011","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"command_injection","year":"2024"},"n_packages":0,"n_references":1,"next":{"headline":"Privilege escalation in Spectrum Power 4","id":"CVE-2024-32014"},"packages":[],"prev":{"headline":"Information disclosure in Spectrum Power 4","id":"CVE-2024-32010"},"products":["Spectrum Power 4"],"published":"2025-11-11","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"total"},"state":"PUBLISHED","updated":"2025-11-12","vendors":["Siemens"]},"summary":"Attackers can execute arbitrary commands as an administrative user via the network-accessible user interface in Siemens Spectrum Power 4.","url":"https://insights.sbomify.com/CVE-2024-32011/"}